PM866K01 3BSE050198R1 Control system using the method

If resistance is encountered when installing a module, do not force the module. Remove the module and check the connectors for bent contacts or foreign objects. Also check to ensure that the module screws are fully retracted. Forcing a module into place may break the connector or bend the securing screws.The MicroNet Simplex main power supplies must have the input power removed before installing or removing. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only. The 24/12 and 16 channel relay modules are for use in ordinary or non-hazardous locations only. Wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction.Installing a Power Supply (PS1, PS2) 1. Be certain power to the supply being installed is disconnected. Verify that all pins in the module connectors are parallel and straight. 2. Install a new power supply by aligning the circuit board edges in the card guides, then pushing the unit into the slots until the connectors on the modules and the connectors on the motherboard make contact. 3. With even pressure exerted at the top and bottom of the supply’s front panel, firmly push the unit into place. Alternatively, apply force to the extraction handle. 4. Tighten the screws that secure the module in place.

Installing the 16/32 Channel Relay Boxes

 The system’s relay boxes mount on a panel (not provided). Mount the relay boxes within the length of the provided cable from the control’s main chassis, leaving adequate service loop. 1. Mark the location of the relay box and the locations of the holes to be drilled to mount it. Figures 15-2 and 15-3 are outline drawings of the relay boxes. 2. Drill and tap holes for appropriately sized hardware. 3. Place the relay box in position. Place the mounting screws into the holes that were drilled and tapped, and tighten them securely. 4. The mounting panel should be well grounded to protective earth via the cabinet structure or ground straps that are low RF impedance. Low RF impedance: length not greater than 4 times the cross-sectional circumference of the ground strap. 5. Additionally, the insulation on the cable between the FTM or relay box and the VME Module may have the insulation removed and a metal “P-clip” used around the cable to ground it within approximately 300 mm (12 inches) of the relay box connector. The requirement for implementing an additional ground is specified in 15.2.6.2 and 15.2.7.2. In all cases the labeled chassis ground connections must also be implemented. 6. If your system includes a second relay box, repeat the above steps for the second relay box. 7. After the FTM, the VME module, and the relay box(es) are installed, the cables that connect them may be installed.

Conditions of UL Acceptability for 32 Channel Relay Box

 1. The devices must be installed in compliance with the enclosure, mounting, spacing, and segregation requirements of the ultimate application. 2. The device(s) must be wired in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction. 15.2.5—Installing FTMs The system’s Field Terminal modules (FTMs) mount on a standard DIN (35 x 7.5) rail (not provided). Mount FTMs within the length of the provided cable from the control’s main chassis, leaving an adequate service loop. 1. Cut a DIN rail strip to the desired length and mount it to a panel. Leave sufficient space between the DIN rail and other objects for accessibility. 2. Drill and tap at least two holes per 300 mm (12 in) for appropriately sized hardware, and secure the DIN rail using screws and washers. 3. The mounting panel should be well grounded to protective earth via the cabinet structure or ground straps that are low RF impedance. Similarly the DIN rail should be well grounded to the panel. Low RF impedance: length not greater than 4 times the cross-sectional circumference of the ground strap.

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

f5a1d52084176089c442c690694264a9.jpg

2c4bec31c236b41fd24170d057dd7bd4.jpg


Get the latest price?