Cable Entry Locations  The cabinet must provide a shield termination point for cables as they enter the enclosure. Shielded I/O shields must be either AC or DC terminated directly to the cabinet (earth ground) at the entry to the cabinet, as well as connected to the FTM shield pins.  Cable shield termination hardware must be installed at cable entry points.  Cable shield terminations must be electrically connected to structural frame (<2.5 mΩ), and shall allow direct grounding or AC (capacitive) grounding of cable shields. 15.2.7.5—Equipment Zoning (Segregation) Separate the equipment inside the cabinet into areas:  Analog equipment area  Discrete I/O equipment areas  Shielded I/O area  Un-shielded I/O area  Power area  Light Industrial compliant equipment area  Monitor/kybd/pointing device (HMI if applicable)  Other equipment area Maintain a minimum of 152 mm (6 inches) of separation between areas. Route I/O cable against cabinet metal wall from entry point to I/O module.  Ground I/O cable shield, direct, to cabinet at entry point. o If over braid shielded, ground over braid shield to cabinet - connect inner braid shields at I/O module termination point. The inner braid must still be directly grounded to earth at one point. o If single shield, ground shield to cabinet.  If field I/O cable is grounded direct (DC coupled) at remote end of cable, ground the I/O cable shield capacitively at I/O module in cabinet and at the cable entry point into the cabinet.

—Input Power Routing and Filtering 

 Input power must enter the cabinet and be routed separately from all other circuits.  Route power in middle at back of cabinet. All other I/O and internal cabling must be kept more than 152 mm (6 inches) away.  Input power must route directly to controls that are Industrial compliant.  Input power that must route to controls that are Light Industrial compliant must be filtered with a minimum of 20 dB filtering.  Input power that must be routed near other cabling will be filtered prior to the point they are on a common path and before leaving the cabinet. Filter with a 20 dB filter. Light Industrial equipment is defined as equipment that is designed and tested to comply with European Union (EU) directives (e.g. EN61000-6-1 or EN61000-6-3) for Light Industrial environments. Industrial compliant equipment is designed and tested for the EU directives for Heavy Industrial environments.I/O Module (FTM & Similar, Analog Driver, etc.) in Cabinet  Use shielded cable from MicroNet module to I/O module  Locate I/O module as close to I/O cable entry point as possible  Locate I/O module away from unshielded discrete areas (> 152 mm (6 inches))

—Shielded Discrete I/O Routing and Shield 

Termination I/O Module (FTM & Similar, Relay Driver, etc.) in Cabinet  Use shielded cable from MicroNet module to I/O module  Ground cable shield, direct, at MicroNet module and I/O module. Striping cable installation and adding a P-clamp type termination within 15 cm (6 inches) if the FTM / Relay Box.  Locate I/O module as close to field I/O cable entry point as possible  Locate I/O module away from shielded analog I/O areas (> 152 mm / 6 inches)  Locate I/O module away from areas with unshielded discrete I/O (> 152 mm / 6 inches) Field I/O Cable with I/O Module (FTM & Similar, Relay Driver, etc.) in Cabinet  Route I/O cable against cabinet metal wall/structure from cabinet entry point to I/O module;  If I/O cable is shielded, ground the I/O cable shield, direct, to cabinet at entry point. o If over braid shielded, ground over braid shield to cabinet - connect inner braid shields directly to earth ground at one point only o If single shield, ground shield to cabinet o If field I/O cable shield is grounded direct at remote end of cable, ground the I/O cable shield, capacitively at the entry point to the cabinet  I/O cable shield ground at the I/O module must be the same type as at cable entry point into cabinet, and it should be direct.

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

f5a1d52084176089c442c690694264a9.jpg

2c4bec31c236b41fd24170d057dd7bd4.jpg


Get the latest price?