B&R 7AO352.70 Drive application process

A data set function for communication on Advant Fieldbus 100. In the controller the DataSet Peripheral is represented with a data base element. Drop Cable The cable from a communication interface or coaxial modem to the coaxial bus cable. EventSet Time tagged events that are sent from an Advant Controller 70, Advant Controller 110/160 to an Advant Controller 400 Series and AC 100 OPC Server. Grounded 75 Ohm BNC Termination, 75 Ohm BNC Termination Each coaxial bus segment must be terminated with a 75 ohm BNC terminator in each end and one of the ends must be grounded. The grounded end should be in a cabinet where one or more communication interfaces are located.

Grounded Twisted pair Termination 

Each twisted pair bus segment must be terminated with a terminator in each end and one of the ends must be grounded. The grounded end should be in a cabinet where one or more communication interfaces are located. Also ground the shield on the same place there the terminator ground. See also Termination and Grounding of Twisted Pair cables on page 175. Modem Cable The cable from the interface devices to the modems. Optical Modem An optical modem is a device that connects the electrical bus with the optical bus fiber cable. Passive device A device that does not have a valid configuration, its configuration is different from the bus master.

7AO352.70.jpg

Redundant Cable 

The communication can have redundant cables, that means, from a communication interface there are two physical ways to any other communication interface in the network. S800 I/O Station S800 Series I/O station in the Advant family. The station, which interfaces AF 100, is subordinated an Advant Controller and is used to distribute the controller I/O along the bus. Segment See Bus segment Signal address, Signal identity Unique identifier of cyclic data packet (CDP) on the bus. The signal identity are equal in the sending and receiving CDP. Station See AF 100 Station. Tap Cable The cable between a twisted pair modem TC512/TC516 or the built in modem in CI627 and the TC505/TC506 connection unit. The tap cable is a part of the twisted pair bus cable

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on