Home > Product > DCS control system > CON021 Displacement sensor

  • CON021 Displacement sensor
  • CON021 Displacement sensor
  • CON021 Displacement sensor
CON021 Displacement sensor CON021 Displacement sensor CON021 Displacement sensor

CON021 Displacement sensor

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

CON021 Displacement sensor

Setting MaxMin This parameter enables the following operating modes to be selected:  MAX (1ph): Pick-up when the highest phase current exceeds the setting.  MAX (3ph): Pick-up when the lowest phase current also exceeds the setting. This setting is not permitted, if the function is set to single-phase measurement.  MIN (1ph): Pick-up when the lowest phase current falls below the setting.  MIN (3ph): Pick-up when the highest phase current also falls below the setting. This setting is not permitted, if the function is set to single-phase measurement.  MAX-Inrush: Pick-up when the highest phase current exceeds the setting with blocking for inrush currents. Operation of the inrush blocking feature (parameter MaxMin set to 'MAX-Inrush') The inrush detector picks up and blocks operation of the function when the amplitude of the fundamental component of the current exceeds the setting of the current function. The inrush detector is based on the evaluation of the second harmonic component of the current I2h in relation to the fundamental frequency component I1h (evaluation of the amplitudes). The output of the function is disabled when the ratio I2h/I1h exceeds 10 % and enabled again when it falls below 8 %. There is no setting for the peak value of I2h/I1h. The function can operate with inrush blocking in both the single and three-phase mode (parameter 'NrOfPhase'). In the three-phase mode, the phase used for evaluation is the one with the highest amplitude at rated frequency (pick-up and inrush detection).

Directional definite time overcurrent protection 

(DirCurrentDT) A. Application Directional overcurrent function for  detecting phase faults on ring lines  detecting phase faults on double-circuit lines with an infeed at one end  backup protection for a distance protection scheme. B. Features  directionally sensitive three-phase phase fault protection  insensitive to DC component  insensitive to harmonics  voltage memory feature for close faults. C. Inputs and outputs I. C.t./v.t. inputs  current  voltage II. Binary inputs  Blocking  PLC receive III. Binary outputs  start  start R  start S  start T  forwards measurement  backwards measurement  tripping IV. Measurements  current amplitude of the three phase currents (IR, IS, IT)  active power A positive measurement indicates the forwards direction (IR * UST, IS * UTR, IT * URS)  voltage amplitude Amplitudes of the phase-to-phase voltages (UST, UTR, URS).

Obtain the latest price of CON021 Displacement sensor