Home > Product > DCS control system > PP846A 3BSE042238R2 Operation panel

  • PP846A 3BSE042238R2 Operation panel
  • PP846A 3BSE042238R2 Operation panel
  • PP846A 3BSE042238R2 Operation panel
PP846A 3BSE042238R2 Operation panel PP846A 3BSE042238R2 Operation panel PP846A 3BSE042238R2 Operation panel

PP846A 3BSE042238R2 Operation panel

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

PP846A 3BSE042238R2 Operation panel

Overvoltage setting (V-Setting) Please note that, although a setting of 2.0 UN is permitted, the measuring range of the c.t./v.t. input channels is only 1.3 UN (i.e. 130 V resp. 260 V max.). The first stage is intended for moderate overvoltages of long duration. The second stage provides protection against high overvoltages and is set to 70 % of the stator test voltage. Where the rated voltages of the protected unit and the v.t's differ, the primary pick-up value in p.u. does not agree with the setting of the protection and this has to be compensated using the reference value of the A/D channel. For example, for a generator rated voltage of UGN = 12 kV and a primary v.t. rated voltage of U1N = 15 kV, the setting of the second stage is 1.4 U U 1.4 12 15 1.12 GN 1N   Over/undervoltage setting (MaxMin) This parameter enables the following operating modes to be selected: MAX (1ph): Pick-up when the highest phase voltage exceeds the setting.

Definite time stator earth fault (95 %)

Overvoltage setting (V-Setting) Please note that, although a setting of 2.0 UN is permitted, the measuring range of the c.t./v.t. input channels is only 1.3 UN (i.e. 130 V resp. 260 V max.). The first stage is intended for moderate overvoltages of long duration. The second stage provides protection against high overvoltages and is set to 70 % of the stator test voltage. Where the rated voltages of the protected unit and the v.t's differ, the primary pick-up value in p.u. does not agree with the setting of the protection and this has to be compensated using the reference value of the A/D channel. For example, for a generator rated voltage of UGN = 12 kV and a primary v.t. rated voltage of U1N = 15 kV, the setting of the second stage is 1.4 U U 1.4 12 15 1.12 GN 1N   Over/undervoltage setting (MaxMin) This parameter enables the following operating modes to be selected: MAX (1ph): Pick-up when the highest phase voltage exceeds the setting.

Settings: Voltage V-Setting Delay Delay The definite time stator E/F scheme (95%) is designed for the protection of generators of generator/transformer units. Description The standard zone of protection of generators of generator/transformer units is 95 % of the length of the stator winding (see Fig. 3.5.10.2). It is normal to limit the zone to 95 % to avoid any risk of false tripping. The stator E/F function is connected either to the v.t. at the stator star-point or to the v.t's at the generator terminals. In both cases, the function monitors the displacement of the star-point caused by a stator E/F. The corresponding off-set voltage becomes a maximum for an E/F at a generator terminal and zero for an E/F at the star-point (see Fig. 3.5.10.2).

Obtain the latest price of PP846A 3BSE042238R2 Operation panel