Home > Product > Servo control system > HIMA Z7138 digital conversion card

  • HIMA Z7138 digital conversion card
  • HIMA Z7138 digital conversion card
  • HIMA Z7138 digital conversion card
HIMA Z7138 digital conversion card HIMA Z7138 digital conversion card HIMA Z7138 digital conversion card

HIMA Z7138 digital conversion card

HIMA Z7138 digital conversion card

For example, a CPU is in RUN IO ENABLED mode and a SVC_REQ 13 function block is executed to place the CPU into STOP IO DISABLED mode. Before the transition to STOP IO DISABLED is completed, the RUN/STOP switch is changed from RUN IO ENABLED to RUN IO DISABLED. In this case, the CPU ignores the new request from the RUN/STOP switch to go to RUN IO DISABLED mode because it is already processing a request to go to STOP IO DISABLED mode and STOP mode has a higher priority than RUN mode. Nuisance faults sometimes logged for missing power supply If a power supply is missing or has some fault that makes it appear to be missing, the CPU may improperly report (upon download of configuration) more than one fault. Such additional faults may be safely ignored and will not occur in a properly configured rack (with no mismatches or missing modules), Uploaded controller supplemental files lose date and time Controller supplemental files uploaded from the CPU are time stamped as 8/1/1980 12:08AM regardless of PC or PLC time.

Ethernet disconnect during word-for-word change 

If the Ethernet connection is broken during a word–for-word change, the programmer may not allow a subsequent word-for-word change after reconnecting due to the fact that it thinks another programmer is currently attached. If this occurs, you should go offline and then back online again. Possible PME inability to connect Infrequently, an attempt to connect a programmer to an RX3i via Ethernet will be unsuccessful. The normal connection retry dialog will not be displayed. Rebooting the computer that is running the programmer will resolve the behavior. Spurious Ethernet fault In rare instances, after power cycle, the Ethernet Interface may log the following fault, Event = 28h, Entry 2 = 000Eh. This fault can be safely ignored. Intermittent Ethernet log event 8H/15H after power cycle When starting after a power cycle, the Ethernet Interface may intermittently log an exception (entry 8H, Entry 2 = 15H, Entry 3 = 0000H, Entry 4 = 00aaH). This exception is benign and may be ignored.

BOOTP and the SetIP tool in PME are not supported. 

The embedded Ethernet Interface cannot operate on a network until a valid IP address is configured. (The default IP address is 192.168.0.100.) The Ethernet addressing information must be configured prior to actual network operation, or to recover from inadvertent changes to the Ethernet addressing data at the Ethernet Interface. Use one of the following methods to initially assign an IP address:  Download a CPE configuration from the Programmer using a serial connection.  Download a CPE configuration from the Programmer using the Ethernet connection of an ETM001 in the same rack with a known IP address configuration. Note: IP Address configuration is not provided when a CPE310 is configured as a CPU310. Programmer version requirements Proficy Machine Edition Logic Developer PLC 7.00 SIM3 or later must be used to configure the embedded Ethernet port of a CPE310. If the embedded port is not needed, older versions of Proficy Machine Edition Logic Developer PLC can be used to download CPU310 configuration to the CPE310.

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

微信图片_20211215171046.jpg

Obtain the latest price of HIMA Z7138 digital conversion card