Home > Product > DCS control system > HONEYWELL LCNP4E 51405098-100 module

  • HONEYWELL LCNP4E 51405098-100 module
  • HONEYWELL LCNP4E 51405098-100 module
  • HONEYWELL LCNP4E 51405098-100 module
HONEYWELL LCNP4E 51405098-100 module HONEYWELL LCNP4E 51405098-100 module HONEYWELL LCNP4E 51405098-100 module

HONEYWELL LCNP4E 51405098-100 module

HONEYWELL LCNP4E 51405098-100 module

The analog output mode switch (S3), shown in Figure 3-1, selects the mode of each analog output. The mode can be set to current (4 to 20 mA) or voltage (1 to 5 VDC). Set the switch to position C1 for a current output at AO1 or position C2 for a voltage output at AO1. Set the switch to position C3 for a current output at AO2 or position C4 for a voltage output at AO2. Figure 3-4 shows the analog output mode switch (S3). Refer to Table 3-3 for the switch settings.Jumpers J-1 through J-3 set the input voltage levels and jumpers J-4 through J-6 set the DC voltage response time. The DC inputs have two propagation (speed) choices: a slow setting (17 millisecond response time) or fast setting (1.5 millisecond response time). There are four terminals at each of these jumper locations. Refer to Table 3-4 to determine the jumper settings for your application; place a jumper across the pins shown in the table. Figure 3-1 shows the location of the jumpers on the IMCIS02.

Termination Unit/Module Configuration 

A TU/TM connects the field device wiring to the Infi 90 system. The terminal blocks (connection points) are located on the TU/ TM. You must configure the TU/TM to accept the field inputs that are sent to the CIS module, and to output the CIS signals that are sent to the process field device. Refer to the appendices to determine the configuration for your application.NOTE: The Installation section provides instructions pertaining to the physical installation of the slave only. For complete cable and TU/TM information, refer to Termination Unit Manual I-E93-911. The IMCIS02 module inserts into a standard Infi 90 Module Mounting Unit (MMU) and occupies one slot. To install: 1. Verify the slot assignment of the module. 2. Verify that a dipshunt is in the slave expander bus socket on the MMU backplane between the slave and master module.

Disconnect power before installing dipshunts for slave modules on the MMU back plane (slave expander bus). Failure to do so could result in severe or fatal shock. AVERTISSEMENT Couper l'alimentation avant d'installer les dipshunts sur la plaque arriere du chassis de montage de modules (MMU). Toute negligence a cet egard constitue un risque de choc pouvant entrainer des blessures graves, voire moretiles.

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

微信图片_20221018155010.jpg

Obtain the latest price of HONEYWELL LCNP4E 51405098-100 module