Multilin MIVII3000E00HI Relay
Product Details Introduction
Multilin MIVII3000E00HI Relay
Main functions and features
Protection function
Overcurrent protection: Provides overcurrent protection for equipment, including short circuit and overload protection.
Differential protection: used to detect internal faults in equipment and achieve protection by comparing the incoming and outgoing currents of the equipment.
Overvoltage/undervoltage protection: Monitor voltage levels to prevent equipment damage due to high or low voltage.
control function
Automatic reclosing: After detecting transient faults, automatic reclosing operation is performed to improve system recovery capability.
Load control: supports automatic control and optimization of loads to improve the efficiency of the power system.
Monitoring and Alarm
Fault monitoring: Real time monitoring of equipment operation status, recording fault information and events.
Alarm system: Provides multiple alarm methods, such as sound and light alarms and remote alarms, to help operators respond in a timely manner.
Communication ability
Remote monitoring: Supports remote monitoring and control through the network for easy system management.
Multiple communication protocols: Supports common communication protocols such as Modbus, IEC 61850, DNP3 for integration with other systems.
user interface
Display Screen: Equipped with an LCD screen, it displays real-time data and system status for easy operation and monitoring.
Operation interface: Provides an intuitive operation interface to simplify the setup and debugging process.
Environmental adaptability
Industrial grade design: The design meets industrial grade standards and can operate stably under various environmental conditions.
Wide temperature range: Suitable for different working environment temperatures to ensure equipment reliability.
application area
Power system
Power plant: used for equipment protection and control in power plants, ensuring the safe operation of generators and transformers.
Substation: Provide protection for transformers and other equipment in the substation to ensure the stability of power transmission.
Industrial facilities
Equipment protection: Protecting critical equipment such as motors and pumps in industrial facilities to prevent damage caused by malfunctions.
Automated Control: Provides automated control functions to optimize production processes and improve efficiency.
distribution network
Transformer protection: used for transformer protection in distribution networks to prevent problems caused by overload or faults.
Load management: Implement load management and optimization to improve the operational efficiency of the power system.
Commercial buildings
Building management system: protects electrical equipment in commercial buildings, ensuring the continuity and safety of power supply.
System monitoring: Provides real-time monitoring and control functions to ensure the stable operation of the power system inside the building.
renewable energy
Wind farms and solar power plants: protect the equipment in wind farms and solar power plants to ensure the stable operation of renewable energy systems.
System optimization: Optimize the load distribution and protection of renewable energy systems to improve system efficiency.
Product advantages
Comprehensive protection: Provides multiple protection functions to ensure the safe operation of equipment.
High performance: high-precision measurement and fast response, improving system stability and reliability.
User friendly: The intuitive user interface and display screen simplify the operation and monitoring process.
Flexible configuration: Supports multiple communication protocols and configuration options to meet the needs of different application scenarios.
Environmental resistance: Designed for various industrial environments and adaptable to different working conditions.
technical parameter
Power Supply Voltage: Supports a wide range of power input and adapts to different power systems.
Measurement accuracy: High precision current and voltage measurements ensure the accuracy of protection functions.
Communication interface: Provides multiple communication interfaces, supports data transmission and system integration.
Work environment: Complies with industrial environmental standards, has environmental resistance, and can adapt to various temperature and humidity conditions.
The Multilin MIVII3000E00HI relay, as an important protective device in the power system, ensures the stable operation of the system and the safety of the equipment through its multifunctional protection and control capabilities
Product image
Related products:
ABB UN0807C-P Programmable Controller
HE700GEN200 Network Interface Module
DEIF LSU-113DG voltage regulator
Other website links
ABB REG670 1MRK002826-AC 安全系统组件
More inventory models
105-070001-05 | HG934A6 | IMAOM01 |
105-090001-01 | HA40A6 | IMAS001 |
105-040200-02 | SL5120RGACB | IMAS011 |
105-0730010-01 | P8101Z20000020 | IMASI02 |
105-094001-01 | HM304A606 | IMASI03 |