Home > Product > DCS control system > Multilin L90A00HCHF8AH6 Relay Panel

  • Multilin L90A00HCHF8AH6 Relay Panel
  • Multilin L90A00HCHF8AH6 Relay Panel
  • Multilin L90A00HCHF8AH6 Relay Panel
Multilin L90A00HCHF8AH6 Relay Panel Multilin L90A00HCHF8AH6 Relay Panel Multilin L90A00HCHF8AH6 Relay Panel

Multilin L90A00HCHF8AH6 Relay Panel

  • Goods status: new/used
  • Delivery date: stock
  • The quality assurance period: 365 days
  • Phone/WhatsApp/WeChat:+86 15270269218
  • Email:xiamen2018@foxmail.com
  • Tags:
  • Get the latest price:Click to consult

Multilin L90A00HCHF8AH6 Relay Panel

Product Details Introduction

The Multilin L90A00HCHF8AH6 relay panel is a key component in the GE Multilin series, mainly used for protection and monitoring in power systems. This relay panel is typically used to integrate and manage multiple protection functions, ensuring the stability and reliability of the power system. The following are the main features, functions, and application areas of the relay panel:

Main features and functions

Protection function

Overcurrent protection: Provides overcurrent protection that can detect and respond to overcurrent situations in the system, preventing equipment damage.

Undervoltage protection: used to monitor system voltage and prevent equipment failure caused by low voltage.

Overvoltage protection: Monitor system voltage to prevent damage to equipment caused by high voltage.

Frequency protection: Monitor the system frequency to ensure that it is within the allowable range and prevent abnormal equipment operation.

Monitoring and Control

Real time monitoring: Continuously monitor the system status, provide real-time data and alarm information, and help operators discover and handle problems in a timely manner.

Control function: Supports automated control functions, such as switch control, circuit breaker operation, etc., to achieve automatic protection and recovery of the system.

communication interface

Multi protocol support: Supports multiple communication protocols such as Modbus, DNP3, IEC 61850, etc., ensuring compatibility with other systems and devices.

Interface options: Typically equipped with multiple communication interfaces (such as Ethernet RS-232、RS-485), Facilitating data exchange and system integration.

user interface

Display screen: Equipped with an LCD display screen, providing an intuitive user interface that displays system status, parameter settings, and alarm information.

User interface: The graphical user interface simplifies the configuration and management process, allowing users to easily set and adjust parameters.

high reliability

Industrial grade design: Meets industrial grade standards and can operate stably in harsh environmental conditions.

Anti interference capability: It has the ability to resist electromagnetic interference and noise, ensuring communication stability in complex environments.

Diagnostic function

Event recording: Recording and storing important event and fault information helps with fault analysis and system maintenance.

Waveform capture: Capture electrical waveform data for detailed analysis and optimization of protection settings.

application area 

transformer substation

Equipment protection: used in substations to protect equipment from damage caused by abnormal current, frequency, or voltage.

System monitoring: As part of the substation protection system, it provides comprehensive monitoring and control functions.

Distribution system

Feedline protection: provides protection for feeders in the distribution system to prevent system problems caused by faults.

Automated Control: Supports automated control functions such as fault isolation and recovery, enhancing system reliability and stability.

Industrial power system

Equipment protection: Provide protection for critical equipment in industrial power systems to ensure stable operation of the equipment.

System integration: Integrate with other control systems to provide comprehensive automation solutions.

Power transmission

Line loss protection: Monitor the status of power transmission lines to protect them from overcurrent and other abnormal conditions.

Stability maintenance: Ensure the stability and reliability of the power transmission system during operation.

summary

The Multilin L90A00HCHF8AH6 relay panel is a high-performance protection and monitoring component with multiple protection functions and powerful monitoring capabilities. Its high reliability design, multi protocol support, and comprehensive user interface make it widely applicable in substations, distribution systems, industrial power systems, and power transmission fields.

Product image

24f2872baf6816a3745ac68a8419737c_1-240I01ZJ3517.jpg

Related products:

ABB XXD129A01 Card Module Controller

AMAT 0190-66253 Communication Module

RADISYS 061-05927-0031 adapter module

Other website links

ABB GDD471A001 接口板模块

GE VMIVME-017807-414001 直流信号输出模块

KOLLMORGEN S22460-SRS 伺服驱动器

More inventory models

PMB33F-20116-0170FV01B-ER45GCAA-R2-NS-VS-00
PMB33F-20100-0370PR 03d-ER32GEAP-R2-NS-VS-00
PMB33F-20100-0270PR05B-ESR33GENT-TS-NS-NV-03
PMB33F-20214-0170SL05AR22HSNA-R1-NS-NV-04
PMB33F-20200-02CT 370aR35KENC-R2-NS-VS-00
PMB33F-20201-01DC 371aR45-GENA-R2-NS-NV-00
PMB33F-20216-00DD 371aR35KENP-R2-NS-NV-00
PMB33F-20201-03DT 370aR23GENA-R1-NS-VS-01


Obtain the latest price of Multilin L90A00HCHF8AH6 Relay Panel