Multilin MIB30HICE00000 is a relay module in the GE Multilin series, commonly used for protection and control of power systems. Although the detailed information of specific models may vary, generally speaking, MIB30HICE00000 is a multifunctional relay module mainly used for power protection and monitoring. Here are some common functions, features, and application areas of this relay module:

Main functions and features

Protection function:

Multiple protection functions: Provides comprehensive protection functions, including overcurrent protection, undervoltage protection, overvoltage protection, short circuit protection, etc.

Custom protection settings: Users can customize protection parameters according to specific needs to adapt to different application scenarios.

Real time monitoring:

Data collection: Real time collection of parameters such as current, voltage, and power to monitor the operating status of the system.

Status indication: Real time display of the working status and fault information of the relay through the display screen or indicator light.

Communication ability:

Communication Protocol: Supports multiple communication protocols such as Modbus, DNP3, IEC 61850, etc., making it easy to integrate with SCADA systems and other monitoring systems.

Data exchange: Implement data exchange with the main control system and support remote monitoring and control functions.

Automated control:

Control function: Provides automated control functions, such as automatic circuit disconnection, remote switch control, etc.

Remote operation: Supports remote operation and configuration, making it easy for operators to manage from a remote location.

User interface:

Operating Interface: Equipped with a user-friendly interface to simplify the configuration and operation process.

Event recording: Record historical events and fault information, provide detailed event logs and fault analysis functions.

Reliability and stability:

Durability: Designed to meet industry standards, it has good durability and stability.

Anti interference: It has the ability to resist electromagnetic interference, ensuring stable operation in harsh environments.

Flexible configuration:

Protection parameter settings: Allow users to flexibly configure protection parameters and control logic according to actual needs.

Widely applicable: Suitable for various power systems and industrial application scenarios, with broad applicability.

application area 

Power distribution system:

Protection function: Used for equipment protection in power distribution systems, ensuring the stability and safety of the system.

Distribution network automation: Improve the automation level of the distribution network, optimize power distribution and fault response.

power plant:

Power generation equipment protection: Protect the generator and its related equipment to ensure the normal operation of the power generation process.

Device Management: Provides comprehensive device management and monitoring functions.

Industrial facilities:

Production line protection: Protect electrical equipment on industrial production lines to prevent equipment failures from affecting production.

Automation control: supports protection and control functions in industrial automation systems.

Building Management:

Building power distribution: a power distribution system used for large buildings to protect electrical equipment inside the building.

Facility monitoring: Enhance the safety and reliability of building power systems.

Water treatment facilities:

Pump station protection: Protect the water pump and related equipment to prevent equipment damage caused by malfunctions.

Process optimization: Improve equipment reliability and safety in water treatment processes.

conclusion

The Multilin MIB30HICE00000 relay module provides a reliable solution for power systems and industrial applications with its comprehensive protection functions, real-time monitoring, automation control, and communication capabilities. It can effectively protect equipment, support remote monitoring and control, and improve system stability and operational efficiency.

Product image

9775b5da333694c967030eb615d38456_1-240I111250S63.jpg

Related products:

RADISYS EXM-HDEXM-MX Memory Module

RADISYS 61-0159-03 CPU circuit board

RADISYS 61-0158-04 CPU Control Card

Other website links

KOLLMORGEN CB06561 PRD-B040SSLZ-62 伺服驱动器

AMAT 0190-07842 印刷电路板

AMAT 0190-30354 接口板模块

More inventory models

PMB33F-10114-01IMAMM033BSE003848R1
PMB33E-10100-02IMASI023BSE003859R1 DSDX 180
PMB31D-00114-01IMASI033BSE003876R1 RC510
PMB33C-00200-00IMASI133BSE003879R1 BB174
PMB31B-10214-03IMASI233BSE003912R1 RF541
PMB31D-10116-00IMASM033BSE004253R1 SX540
PMB31B-00200-01IMASO013BSE004255R1 SX542
PMB32D-00200-02IMASO113BSE004265R1 SV541
PMB33C-10101-02IMBLK013BSE004985R1 DSRF 187


Obtain the latest price of Multilin MIB30HICE00000 relay