Home > Product > DCS control system > YOKOGAWA 8662560000 input module

  • YOKOGAWA 8662560000 input module
  • YOKOGAWA 8662560000 input module
  • YOKOGAWA 8662560000 input module
YOKOGAWA 8662560000 input module YOKOGAWA 8662560000 input module YOKOGAWA 8662560000 input module

YOKOGAWA 8662560000 input module

YOKOGAWA 8662560000 input module

Save Brushless Motor Configuration It is very important to save the brushless motor configuration in non-volatile memory. After the motor wiring and setup parameters have been properly configured, the burn command, BN, should be given. NOTE: Without hall sensors, the controller will not be able to estimate the commutation phase of the brushless motor. In this case, the controller could become unstable until the commutation phase has been set using the BZ command (see next step). It is highly recommended that the motor off command be given before executing the BN command. In this case, the motor will be disabled upon power up or reset and the commutation phase can be set before enabling the motor.

Set Zero Commutation Phase

 When an axis has been defined as sinusoidally commutated, the controller must have an estimate for commutation phase. When hall sensors are used, the controller automatically estimates this value upon reset of the controller. If no hall sensors are used, the controller will not be able to make this estimate and the commutation phase must be set before enabling the motor. To initialize the commutation without Hall effect sensor use the command, BZ. This function drives the motor to a position where the commutation phase is zero, and sets the phase to zero. The BZ command is followed by real numbers in the fields corresponding to the driven axes. The number represents the voltage to be applied to the amplifier during the initialization. When the voltage is specified by a positive number, the initialization process end up in the motor off (MO) state. A negative number causes the process to end in the Servo Here (SH) state.

With hall sensors

 the estimated value of the commutation phase is good to within 30°. This estimate can be used to drive the motor but a more accurate estimate is needed for efficient motor operation. There are 3 possible methods for commutation phase initialization: Method 1. Use the BZ command as described above. Method 2. Drive the motor close to commutation phase of zero and then use BZ command. This method decreases the amount of system jerk by moving the motor close to zero commutation phase before executing the BZ command. The controller makes an estimate for the number of encoder counts between the current position and the position of zero commutation phase. This value is stored in the operand _BZn. Using this operand the controller can be commanded to move the motor. The BZ command is then issued as described above.

10.28.jpg

Obtain the latest price of YOKOGAWA 8662560000 input module