Home > Product > DCS control system > CE3007 KJ2005X1-BA1 12P4375X042 CPU module

  • CE3007 KJ2005X1-BA1 12P4375X042 CPU module
CE3007 KJ2005X1-BA1 12P4375X042 CPU module

CE3007 KJ2005X1-BA1 12P4375X042 CPU module

CE3007 KJ2005X1-BA1 12P4375X042 CPU module

The second method for setting an IP address is to send the IA command through the DMC-21x2/21x3 RS-232 port. The IP address you want to assign may be entered as a 4 byte number delimited by commas (industry standard uses periods) or a signed 32 bit number. (Ex. IA 124,51,29,31 or IA 2083724575) Type in BN to save the IP address to the controller’s non-volatile memory. NOTE: Galil strongly recommends that the IP address selected is not one that can be accessed across the Gateway. The Gateway is an application that controls communication between an internal network and the outside world. To decide on an IP address, find the address of the computer the controller will be connecting to, then find the computer’s Subnet Mask. (In Windows, open a DOS prompt and type ipconfig). The fields of the subnet mask that contain a “255” require that the corresponding fields in the IP address of the controller be the same as the IP address of the PC. For instance, if the Subnet Mask of the PC is 255.255.0.0, and the IP address is 192.168.100.10 – then the controller’s IP address should be set to 192.168.nnn.nnn where nnn can be anything from 0-255.

The third level of Ethernet addressing

 is the UDP or TCP port number. The Galil controller does not require a specific port number. The port number is established by the client or master each time it connects to the controller.

CAUTION: Be sure that there is only one BOOT-P server running. If your network has DHCP or BOOT-P running, it may automatically assign an IP address to the controller upon linking it to the network. In order to ensure that the IP address is correct, please contact your system administrator before connecting the controller to the Ethernet network.

Communicating with Multiple Devices 

The DMC-21x3 is capable of supporting multiple masters and slaves. The masters may be multiple PC’s that send commands to the controller. The slaves are typically peripheral I/O devices that receive commands from the controller. NOTE: The term “Master” is equivalent to the internet “client”. The term “Slave” is equivalent to the internet “server”. An Ethernet handle is a communication resource within a device. The DMC-21x2/21x3 can have a maximum of 8 Ethernet handles open at any time. When using TCP/IP, each master or slave uses an individual Ethernet handle. In UDP/IP, one handle may be used for all the masters, but each slave uses one. (Pings and ARP’s do not occupy handles.) If all 8 handles are in use and a 9th master tries to connect, it will be sent a “reset packet” that generates the appropriate error in its windows application.

Temporal Ming sheng automation equipment co., LTD., specialized in (DCS system) (robotic system) (large) servo control system (PLC system) module for spare parts sales, inventory adequate, product quality, let you have no trouble back at home of our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on

Brand advantage

GE gas turbine electric, ABB, Bently bentley, Emerson Emerson, Honeywell Honeywell, ICS Triplex, WOODWARD WOODWARD, FOXBORO FOXBORO, SST, HIMA hermas, Motorola Motorola, TRICONEX invensys, SCHNEIDER SCHNEIDER A - B, Prosoft import module in Europe and America and so on


Obtain the latest price of CE3007 KJ2005X1-BA1 12P4375X042 CPU module