This field specifies the database address in the module's internal database to use as the destination for data brought in by a read command or as the source for data to be sent out by a write command. The database address is interpreted as a bit address or a 16-bit word (register) address, depending on the Modbus Function Code used in the command. For Modbus functions 1, 2, 5, and 15, this parameter is interpreted as a bitlevel address. For Modbus functions 3, 4, 6, and 16, this parameter is interpreted as a wordlevel or register-level address. Note: When using a bit level command, you must define this field at the bit level. For example, when using function codes 1 or 2 for a Read command, you must have a enter of 16000 to place the data in MNET.DATA.ReadData[0] (The module's internal register 1000 * 16 bits per register = 16000). Use this formula for function codes 5 or 15 for writing bits also
This controller tag is a 16bit signed integer.
This means you can only enter values of -32768 to 32767 in the tag. If a value to be entered is above the 32767 (but below 65535) threshold, it will display as a negative value in the tag. Simply subtract 65536 from the value to get the 'acceptable' value to enter into the tag. Example: You need to use an Internal bit Address of 48000, but you cannot enter '48000' into the tag because it causes an error. 48000 - 65536 = -17536 You need to enter -17536 in the Internal Address parameter for this command.
This parameter specifies the minimum interval between issuances of a command during continuous command execution (Enable code of 1). The parameter is entered in tenths of a second. Therefore, if a value of 100 is entered for a command, the command executes no more frequently than every 10 seconds
This parameter specifies
the number of 16-bit registers or binary bits to be transferred by the command. Functions 5 and 6 ignore this field as they apply only to a single data point. For functions 1, 2, and 15, this parameter sets the number of bits (inputs or coils) to be transferred by the command. For functions 3, 4, and 16, this parameter sets the number of registers to be transferred by the command.
1.Payment method and delivery
Shipment: EMS,DHL,UPS & FEDEX
Payment: T/T or Western Union
2. About us
We are professional company and we are expert in this business, we have highly experienced production team, or sales team, or purchase team, we have most advanced production line. We are reputable in the market.
3. Application industry
Our main products are widely used in metallurgy, oil and gas, glass manufacturing, aluminum, petrochemical, coal mine, paper making and printing, textile printing and dyeing, machinery, electronic manufacturing, automobile manufacturing, tobacco, plastic machinery, electricity, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution, etc.