Home > Product > Robot control system > KOKUSAI SMPCONT-A3B Main control circuit board

  • KOKUSAI SMPCONT-A3B  Main control circuit board
  • KOKUSAI SMPCONT-A3B  Main control circuit board
  • KOKUSAI SMPCONT-A3B  Main control circuit board
KOKUSAI SMPCONT-A3B  Main control circuit board KOKUSAI SMPCONT-A3B  Main control circuit board KOKUSAI SMPCONT-A3B  Main control circuit board

KOKUSAI SMPCONT-A3B Main control circuit board

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

KOKUSAI SMPCONT-A3B  Main control circuit board

If the terminal is sealed this screen will appear without a START button, and with a Status message that software upgrade will not be permitted when the metrological security switch S-1 is ON (locked). The terminal must be unsealed and the switch set to OFF, in order to permit a software upgrade. 6. By default, the Internal File option is selected in the Install from list. This is the correct setting for upgrade from files downloaded using InSite.

On-screen messages will indicate the progress of the upgrade. Do not disconnect power from the IND780 during this procedure. The terminal will back up existing files, unpack the upgrade files and perform clean-up operations. Once this process is complete, start-up continues as normal. 10. If prompted to do so, manually cycle power to the terminal to complete the process. Upgrade Using USB Memory In general, USB drives that are USB 2.0 certified and 1.1 compatible are supported by the IND780. To perform an upgrade without using a PC with InSite: 1. Create a folder called UPGRADE in the root of a USB Memory drive (“thumb drive”). 2. Copy the two UPGRADE files into the UPGRADE folder. 3. Connect the USB Memory to the IND780’s USB port, either by plugging it in directly or via a USB extension cable connected to the port. 4. Access Setup > Maintenance > Run > Install Software Upgrade, as above

Power Up and Screen Saver Graphics

If the terminal is sealed this screen will appear without a START button, and with a Status message that software upgrade will not be permitted if the metrological security switch S-1 is ON (locked). The terminal must be unsealed and the switch set to OFF in order to permit a software upgrade. 6. If the USB drive is not attached or the folder isn’t present, a Status message will appear – “USB Memory Error.” Otherwise, the terminal will display a message “Copying USB to CF.” Wait while the process is complete, and another message appears – “Unplug USB Memory.” The terminal automatically re-starts. Status messages will indicate that files are being backed up, unpacked and upgraded. Do not turn off power to the terminal during this procedure. 7. If prompted to do so, manually cycle power to the terminal to complete the process.

The graphic used by the IND780 as a splash screen during start up and the image used as a screen saver (which displays when the Screen Saver setting at Terminal > Display has a value other than zero) can both be changed by downloading replacement files to the terminal’s UPGRADE folder. Power Up Graphic The graphic used at power up must be a monochrome bitmap file measuring no more than 320 pixels wide and 140 pixels high. It must be named pwrup.bmp. Screen Saver Graphic The screen saver graphic is also a bitmap file. For color terminals, the bitmap may be in 256 color format. For monochrome terminals, the bitmap should be monochrome. In either case, the image should measure no more than 320 pixels wide and 200 pixels high, and must be named saver.bmp.

Obtain the latest price of KOKUSAI SMPCONT-A3B Main control circuit board