Home > Product > Robot control system > ALSTOM UT150-1 Control card

  • ALSTOM UT150-1 Control card
  • ALSTOM UT150-1 Control card
  • ALSTOM UT150-1 Control card
ALSTOM UT150-1 Control card ALSTOM UT150-1 Control card ALSTOM UT150-1 Control card

ALSTOM UT150-1 Control card

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

ALSTOM UT150-1 Control card

Installing New Graphics Either or both of the power up and screen saver graphics can be installed on the IND780 by making an ftp connection to the terminal via EtherNet, logging on as an administrator (with write privileges), and copying the file/s to the UPGRADE folder. When the terminal is restarted, the files are automatically moved to their correct location, where they replace the existing images. System Backup and Restore Procedures The configuration of an IND780 may be exported (backed up) to and restored from, USB memory. Files can be restored to the original terminal or copied to another IND780, which acquires a configuration identical to that of the original. This permits the restoration of setup should a main PCB require replacement, for example, and allows the creation of functionally identical terminals. Once the backup dataset is copied to a USB drive, it can be saved to a PC. However, for restoration to an IND780 the file must always reside in the directory indicated below.

When the IND780 is backed up, the dataset includes all log files in .csv format. These can be viewed or printed from a PC. To back up files from an IND780: 1. Connect a USB (flash) memory device to the IND780’s USB port, either directly or via a USB extension cord. 2. Access Setup > Maintenance > Run > Backup to USB. The screen shown in Figure 3-6 will appear.

Restore

System Restore cannot be performed if the terminal is locked. An Administrator level login must be in effect to carry out this procedure. A system restore operation does not copy log files from the dataset, and the terminal’s existing log files are not over-written on restore. To restore files to an IND780: 1. Connect a USB (flash) memory device to the IND780’s USB port, either directly or via a USB extension cord. 2. Access Setup > Maintenance > Run > Restore from USB. A screen like the one shown in HFigure 3-7 will appear.

By default, the Dataset Name is BK1; press ENTER to select the field and enter another name, if required. 4. Press the START softkey . The IND780 will check for the presence of a valid USB memory device. On finding one, it checks for available space. If a device is not found, or a device is present that has insufficient space for the operation, a prompt (“USB Memory Error”) informs the operator and the backup does not proceed. If space is available, the IND780 creates a folder titled Mettler Toledo/Backup/IND780/(where “dataset name” is the name entered in step H3), then begins the transfer of data. An on-screen message (“Working”) indicates that the procedure is in progress. 5. Once the terminal indicates that the backup is complete, the USB device can be unplugged and the EXIT softkey pressed to return to the menu tree. 

Obtain the latest price of ALSTOM UT150-1 Control card