Home > Product > DCS control system > ABB PFTL101BE Vertical measurement sensor

  • ABB PFTL101BE Vertical measurement sensor
ABB PFTL101BE Vertical measurement sensor

ABB PFTL101BE Vertical measurement sensor

ABB PFTL101BE Vertical measurement sensor

In this manual, we will describe important cautionary items which should always be observed regarding usage, inspection upon receipt of product, mounting, wiring, operation, and maintenance/inspection.

• Do not bundle or run power and signal lines together in the same duct. Keep power and signal lines at least 11.81” (30cm) apart. 

• Use twisted pair or shielded multi-core twisted pair wires for signal and encoder (PG) feedback lines. 

• The maximum lengths for signal lines are as follows: 

• Maximum of 9.84ft (300cm) for reference input lines. 

• Maximum of 65.6ft (20m) for PG feedback lines. 

• Use a cable type UL20276-SB for distances over 65.6ft (20m).

• To prevent unexpected accidents

test the motor with the motor shaft not connected to a machine or load. 

• To prevent unexpected accidents, run with limit switches or stoppers attached to both ends of the magnet track. Failure to do so may result in injury. 

• Set parameters before operating the motor in connection with a machine.. Operating without making these settings may result in machine runaway and damage.

 • After mounting on the machine, prior to the start of operation, make sure the emergency stop can be applied at any time. Failure to do so may result in injury. 

• Do not touch the heat sink while the unit is running. The high temperature may result in burns.

• Never touch the inside of the digital torque amplifier.

 Doing so may result in electrical shock. 

• Be sure no wiring is exposed when power is turned ON. Failure to do so may result in electrical shock. 

• Do not touch the terminals for five minutes following power OFF. Electrical shock may result due to residual voltage.

• Do not connect a three-phase power supply to the digital torque amplifier output terminals U, V, and W. Doing so may result in injury or fire. 

• Securely fasten the screws for the power terminals and motor terminals. Failure to do say may result in fire.

                                         

Do you want to know about our products?

We have a large amount of inventory and high quality, out of production control system components, DCS system accessories, robot system accessories, large servo system spare parts. PLC module, DCS module, CPU module, IO module, DO module, AI module, DI module, network communication module, Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output module, redundancy module, power module, relay output module, relay input module, processor module and other major brands.