Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
16 channel, Compact FieldPoint drain digital output module - the CFP - DO - 403 provides sinking digital output channel. Each channel has a LED, channel is used to denote the on/off state. In order to simplify the installation and setup, cFP - DO - 403 using HotPnP (plug in) operation, and can automatically detect and identify the configuration software.
CLEAR MIN/MAX CURRENT VALUES: Enter “Yes” to clear all the minimum/maximum current data under the actual values subgroup A1 METERING ÖØ CURRENT. The time and date associated with each message will be updated to the current date upon issuing this command. • CLEAR MIN/MAX VOLTAGE VALUES: Enter “Yes” to clear all the minimum/maximum voltage data under the actual values subgroup A1 METERING ÖØ VOLTAGE. The time and date associated with each message will be updated to the current date upon issuing this command. • CLEAR MIN/MAX POWER VALUES: Enter “Yes” to clear all the minimum/maximum power data under the actual values subgroup A1 METERING ÖØ POWER. The time and date associated with each message will be updated to the current date upon issuing this command. • CLEAR MIN/MAX FREQUENCY VALUES: Enter “Yes” to clear all the minimum/maximum frequency data under the actual values subgroup A1 METERING ÖØ FREQUENCY. The time and date associated with each message will be updated to the current date upon issuing this command.
Enter “Yes” to clear all the max THD data under the actual values subgroup A3 POWER ANALYSIS ÖØ TOTAL HARMONIC DISTORTION. The time and date associated with each message will be updated to the current date upon issuing this command. • CLEAR PULSE INPUT VALUES: Enter “Yes” to clear all the pulse input values under the actual values subgroup A1 METERING ÖØ PULSE INPUT. The time and date associated with this message will be updated to the current date upon issuing this command. • CLEAR EVENT RECORD: Enter “Yes” to clear all of the events in the Event Record. This will eliminate all previous events from the Event Record and create a Clear Events event as the new event number 1. The Event Recorder can be cleared only if it is enabled in S1 PQMII SETUP ÖØ EVENT RECORDER ÖØ EVENT RECORDER OPERATION. The CLEAR EVENT RECORD command takes six seconds to complete, during which no new events will be logged. Do not cycle power to the unit while the event record is being cleared. • CLEAR VOLTAGE DIST. RECORD: Enter “Yes” to clear all of the events in the Voltage Disturbance Record. • LOAD FACTORY DEFAULT SETPOINTS: When the PQMII is shipped from the factory all setpoints will be set to factory default values. These settings are shown in the setpoint message reference figures. To return a PQMII to these known setpoints select “Yes” and press the key while this message is displayed. The display will then warn that all setpoints will be lost and will ask whether to continue. Select yes again to reload the setpoints. It is a good idea to first load factory defaults when replacing a PQMII to ensure all the settings are defaulted to reasonable values.