Home > Product > Gas turbine system > GE DS200TCQEF1A Analog Output Card

  • GE DS200TCQEF1A Analog Output Card
GE DS200TCQEF1A Analog Output Card

GE DS200TCQEF1A Analog Output Card

GE DS200TCQEF1A Analog Output Card

When the data transmission function was used, the error occurred. The data stands for the alarm factor. 1:Retryover of NAK 2:Retryover of timeout in timer A 3:Retryover of mutual response error Correct the error according to the data of the alarm factor after resetting the alarm. 4113 DATA RECEIVING ERROR [Decimal Data] When the data transmission function was used, the error occurred. The data stands for the alarm factor. 1:Reception timeout (timer A) 2:Reception timeout (timer B) 3:Heading length is short. 4:Heading length is long. 5:The heading No. error. 6:The text length exceeds 256 characters

When the data transmission function was used

the error occurred. (Though the transmission procedure is correct, there is a reception that irrationality is caused in system. This error is mainly caused by PC breached the rule or abnormal communication.) The data stands for the alarm factor. 1:Received EOT when waiting ACK. 2:Received EOT when waiting ENQ. 3:Received EOT before last block reception 4:Received codes for except EOT after last block reception. Correct the error according to the data of the alarm factor after resetting the alarm. 4116 TRANSMISSION SYSTEM ERROR [Decimal Data] An error occurs in the internal processing of the transmission system.

The axis was instructed to turn servo on and off separately. 

Make the condition so as to be able to turn servo on and off after resetting the alarm. 4120 IMPOSSIBLE TO DISCONNECT SERVO [Control Group] Some axes were instructed and cannot turn the servo on or off. After resetting the alarm, adjust the axes so that the servo power can be turned on and off. 4121 COOLING FAN 1 ERROR [Binary Data] The number of revolutions of cooling fan 1 connected to the contactor unit was reduced. After resetting the alarm, move the manipulator in the teach mode to a safe place. Contact your Yaskawa representative to replace the cooling fan 1. 4122 COOLING FAN 2 ERROR [Binary Data] The number of revolutions of cooling fan 2 connected to the contactor unit was reduced. After resetting the alarm, move the manipulator in the teach mode to a safe place. Contact your Yaskawa representative to replace the cooling fan 2.

                                        

[Main Products]

Main products: PLC and DCS system spare parts modules of world famous brands

①Allen-Bradley 17561746174717711785

②Schneider 140 Series PLC module

③General electric GE  IC693 IC697 IC698 Series PLC module

DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module

VMIVME Control module of series

④Bently3500 series cards 3500/22M3500/153500/92 And other products

⑤ICS TRIPLEX

⑥ABB Robots. FANUC RobotsYASKAWA RobotsKUKA RobotsMitsubishi RobotsOTC RobotsPanasonic RobotsMOTOMAN Robots

EMERSONSpare parts for OVATION system, WDPF system and MAX1000 system.

⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.

Woodward505 series governor 9907-164 And other products

⑩Bosch RexrothIndramatI/O module,PLC CPU,Motors, drives and other products.

 ◆MotorolaMVME 162MVME 167MVME1772MVME177and other products.

Obtain the latest price of GE DS200TCQEF1A Analog Output Card