Home > Product > Gas turbine system > GE DS200TCQEG1A Analog Output Card

  • GE DS200TCQEG1A Analog Output Card
GE DS200TCQEG1A Analog Output Card

GE DS200TCQEG1A Analog Output Card

GE DS200TCQEG1A Analog Output Card

The number of revolutions of cooling fan 3 connected to the contactor unit was reduced. After resetting the alarm, move the manipulator in the teach mode to a safe place. Contact your Yaskawa representative to replace the cooling fan 3. 4127 U-AXIS TIMING BELT BLOWN An error was detected in the drive belt of the U-axis. Perform an overrun release, move the robot to the posture for replacement, and replace the belt. 4200 SYSTEM ERROR (FILE DATA) [Decimal Data] When acess to the file data was executed, the error occured. (File edition, Operation of external memory unit) • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative.

When access to the job was executed, the error occured.

 (During robot is being playback and operation) • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative. 4202 SYSTEM ERROR(JOB) [Decimal Data] When acess to the job was executed, the error occured. (Job edition, Operation of external memory unit) • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative. 4203 SYSTEM ERROR (POSITION DATA) [Bit Pattern] When acess to the position data was executed, the error occured. (During playback and operation) • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative.

• Reset the alarm and repeat the operation.

 • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative. 4206 SYSTEM ERROR (TRANSMISSION) [Decimal Data] When the data transmission function was used, the error occured. The error of internal procedure for transmission system. Needs investigation. Consult a YASKAWA representative. 4207 SYSTEM ERROR(MOTION) [Decimal Data] The system error occured in MOTION. • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative.

                                        

[Main Products]

Main products: PLC and DCS system spare parts modules of world famous brands

①Allen-Bradley 17561746174717711785

②Schneider 140 Series PLC module

③General electric GE  IC693 IC697 IC698 Series PLC module

DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module

VMIVME Control module of series

④Bently3500 series cards 3500/22M3500/153500/92 And other products

⑤ICS TRIPLEX

⑥ABB Robots. FANUC RobotsYASKAWA RobotsKUKA RobotsMitsubishi RobotsOTC RobotsPanasonic RobotsMOTOMAN Robots

EMERSONSpare parts for OVATION system, WDPF system and MAX1000 system.

⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.

Woodward505 series governor 9907-164 And other products

⑩Bosch RexrothIndramatI/O module,PLC CPU,Motors, drives and other products.

 ◆MotorolaMVME 162MVME 167MVME1772MVME177and other products.

Obtain the latest price of GE DS200TCQEG1A Analog Output Card