Home > Product > Gas turbine system > GE DS200TCQEG2A Analog Output Card

  • GE DS200TCQEG2A Analog Output Card
GE DS200TCQEG2A Analog Output Card

GE DS200TCQEG2A Analog Output Card

GE DS200TCQEG2A Analog Output Card

The system error occured in ARITH. • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative. 4209 OFFLINE SYSTEM ERROR (ARITH) [Decimal Data] The system error occured in ARITH offline. • Reset the alarm and repeat the operation. • Turn the power off then back on. • If the error occurs again, contact your YASKAWA representative. 4220 SERVO POWER OFF FOR JOB [Control Group] The servo power supply was not turned on for the job group axis which was to be operated. Intercept the servo power supply once and turn on the servo power supply to the group axis to be operated.

The servo power supply

 was not turned on for the job group axis which was to be operated. Intercept the servo power supply once and trun on the servo power supply to the group axis to be operated. 4222 SAFE CIRCUIT SIG NOT SAME (XCI01) [Binary Data] The error occurred in the safe circuit signal (I/O contactor unit). (Check the XCI01 circuit board duplication signal.) • Check the safe circuit signal wiring of the cables connected to the I/O contactor unit. • Replace the I/O contactor unit. 4223 SAFE CIRCUIT SIGNAL NOT SAME (SV) [Decimal Data] The error occurred in the safe circuit signal (I/O contactor unit). (Check the WRCA01 board duplication signal.) The data stands for the following error signals: 1: IORDY 2: ON_EN 3: OVSPD 4: SVMAIN 5: EXOT 6: SVMX 7: KMMB 8: KMMA • Check the safe circuit signal wiring of the cables connected to the I/O contactor unit. • Replace the I/O contactor unit.

• The contactor of the contactor unit

 was not turned ON at servo ON. • While turning servo ON, the signal from the contactor was intercepted . • The contactor signal was not intercepted at servo OFF(at emergency stop). • While turning servo OFF(at emergency stop), the contactor signal was turned ON. Reasons are as follows: • Defective contactor unit • Defective WRCA01 circuit board • Turn servo ON again after resetting the alarm. • If the error occurs again, replace the contactor unit, WRCA01 circuit board.

                                        

[Main Products]

Main products: PLC and DCS system spare parts modules of world famous brands

①Allen-Bradley 17561746174717711785

②Schneider 140 Series PLC module

③General electric GE  IC693 IC697 IC698 Series PLC module

DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module

VMIVME Control module of series

④Bently3500 series cards 3500/22M3500/153500/92 And other products

⑤ICS TRIPLEX

⑥ABB Robots. FANUC RobotsYASKAWA RobotsKUKA RobotsMitsubishi RobotsOTC RobotsPanasonic RobotsMOTOMAN Robots

EMERSONSpare parts for OVATION system, WDPF system and MAX1000 system.

⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.

Woodward505 series governor 9907-164 And other products

⑩Bosch RexrothIndramatI/O module,PLC CPU,Motors, drives and other products.

 ◆MotorolaMVME 162MVME 167MVME1772MVME177and other products.

Obtain the latest price of GE DS200TCQEG2A Analog Output Card