The value of pressure in the "GUN PRESSURE" file or the "PRESSURE" file exceeds the maximum pressure in the "GUN CONDITION" file. Change the value of pressure in the "GUN PRESSURE" file or the "PRESSURE" file below the maximum pressure. 4400 NOT READY (ARITH) [Decimal Data] The operation process of motion control does not end in regulated time.
• Reset the alarm and repeat the operation.
• If the error occurs again, contact your YASKAWA representative.
• Reset the alarm and repeat the operation.
• If the error occurs again, contact your YASKAWA representative.
The error occurs in information on the robot
which uses for the job interpretation and the motion control. • Reset the alarm and repeat the operation • If the error occurs again, contact your YASKAWA representative. 4430 CPU COMMUNICATION ERROR [Decimal Data] When interrupting various circuit board from the XCP01 circuit board, interrupted boards were not prepared or didn't respond. • Reset the alarm and repeat the operation. • If the error occurs again, contact your YASKAWA representative. 4431 JHM ERROR [Decimal Data] The data was abnormal in the job control process. • Reset the alarm and repeat the operation. • If the error occurs again, contact your YASKAWA representative.
The error occurred in the job interpretation exec statement part.
• Reset the alarm. Select job and repeat the operation. • If the error occurs again, operate by the following procedure: c Delete the command that caused the alarm and register again and start execution. d Delete the job that cause the alarm and register again and start execution. • If the error occurs again, contact your YASKAWA representative. 4433 UNDEFINED GLOBAL VARIABLE [Decimal Data] The global variable range was undefined. Needs investigation at YASKAWA. Consult a YASKAWA representative.
• Reset the alarm. Select job and repeat the operation. • If the error occurs again, operate by the following procedure: c Delete the command that caused the alarm and register again and start execution. d Delete the job that cause the alarm and register again and start execution. • If the error occurs again, contact your YASKAWA representative.
[Main Products]
Main products: PLC and DCS system spare parts modules of world famous brands
①Allen-Bradley 1756、1746、1747、1771、1785
②Schneider 140 Series PLC module
③General electric GE IC693 IC697 IC698 Series PLC module
DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module
VMIVME Control module of series
④Bently:3500 series cards 3500/22M、3500/15、3500/92 And other products
⑤ICS TRIPLEX
⑥ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦EMERSON:Spare parts for OVATION system, WDPF system and MAX1000 system.
⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.
⑨Woodward:505 series governor 9907-164 And other products
⑩Bosch Rexroth:Indramat,I/O module,PLC CPU,Motors, drives and other products.
◆Motorola:MVME 162、MVME 167、MVME1772、MVME177and other products.