The value of pressure in the "GUN PRESSURE" file or the "PRESSURE" file exceeds the maximum pressure in the "GUN CONDITION" file. Change the value of pressure in the "GUN PRESSURE" file or the "PRESSURE" file below the maximum pressure. 4400 NOT READY (ARITH) [Decimal Data] The operation process of motion control does not end in regulated time. 

• Reset the alarm and repeat the operation. 

• If the error occurs again, contact your YASKAWA representative.

• Reset the alarm and repeat the operation. 

• If the error occurs again, contact your YASKAWA representative.

The error occurs in information on the robot 

which uses for the job interpretation and the motion control. • Reset the alarm and repeat the operation • If the error occurs again, contact your YASKAWA representative. 4430 CPU COMMUNICATION ERROR [Decimal Data] When interrupting various circuit board from the XCP01 circuit board, interrupted boards were not prepared or didn't respond. • Reset the alarm and repeat the operation. • If the error occurs again, contact your YASKAWA representative. 4431 JHM ERROR [Decimal Data] The data was abnormal in the job control process. • Reset the alarm and repeat the operation. • If the error occurs again, contact your YASKAWA representative.

The error occurred in the job interpretation exec statement part.

 • Reset the alarm. Select job and repeat the operation. • If the error occurs again, operate by the following procedure: c Delete the command that caused the alarm and register again and start execution. d Delete the job that cause the alarm and register again and start execution. • If the error occurs again, contact your YASKAWA representative. 4433 UNDEFINED GLOBAL VARIABLE [Decimal Data] The global variable range was undefined. Needs investigation at YASKAWA. Consult a YASKAWA representative.

• Reset the alarm. Select job and repeat the operation. • If the error occurs again, operate by the following procedure: c Delete the command that caused the alarm and register again and start execution. d Delete the job that cause the alarm and register again and start execution. • If the error occurs again, contact your YASKAWA representative.

                                        

[Main Products]

Main products: PLC and DCS system spare parts modules of world famous brands

①Allen-Bradley 17561746174717711785

②Schneider 140 Series PLC module

③General electric GE  IC693 IC697 IC698 Series PLC module

DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module

VMIVME Control module of series

④Bently3500 series cards 3500/22M3500/153500/92 And other products

⑤ICS TRIPLEX

⑥ABB Robots. FANUC RobotsYASKAWA RobotsKUKA RobotsMitsubishi RobotsOTC RobotsPanasonic RobotsMOTOMAN Robots

EMERSONSpare parts for OVATION system, WDPF system and MAX1000 system.

⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.

Woodward505 series governor 9907-164 And other products

⑩Bosch RexrothIndramatI/O module,PLC CPU,Motors, drives and other products.

 ◆MotorolaMVME 162MVME 167MVME1772MVME177and other products.