Home > Product > Gas turbine system > GE DS200TCCAG2B Gas turbine card

  • GE DS200TCCAG2B Gas turbine card
GE DS200TCCAG2B Gas turbine card

GE DS200TCCAG2B Gas turbine card

GE DS200TCCAG2B Gas turbine card

It is absolutely necessary to run cable shields completely up to the connectors. The connection of the cable shields to ground must be near the servo regulator (10 - 50 cm). Sensitive measuring leads should be as far as possible from this area; this applies also when they are shielded! It is mandatory to run the motor cables in a separate cable channel and to lay flexible cable shielding also when these are shielded. This channel must be separated at least 30 - 40 cm from the channel for the signal lines.Static Application: blocks the motor shaft at standstill ¾ Dynamic Application: only in an emergency stop situation. In this situation, the brake has approximately half of the holding torque capacity as when the motor is idle. The number of such braking events is limited.

The inserted brake is not designed for the purpose 

of slowing down the motor, but is designed to serve as merely a standstill and/or holding brake. Therefore, the operator must be certain that the motor is not moving before the brake is engaged. Should the brake not be employed as directed, then the holding torque capacity of the brake will be affected, depending upon a number of variables, including but not limited to the following: ¾ the speed of the drive when the brake is engaged ¾ the load moment of inertia on the driver ¾ environmental conditions, such as temperature, humidity, etc. ¾ the number of times that the brake is engaged and so forth

Nominal Power 

 Dependence upon the Installation Altitude of the Servo Motor When selecting an appropriately sized motor, the following needs to be considered: Workload (power), operating mode, starting, braking and by-pass processes, additional moment of inertia and additional characteristics of the equipment installation, including speed control if necessary, net ratios, coolant temperature, installation altitude etc. The nominal power is the power that is mechanically available at the drive shaft, if the installation site is not located above 1,000 meters above sea level, (MSL), the air temperature does not exceed 40° C, and the net ratios are normal. With differing installation parameters concerning installation altitude and air temperature

                                        

 Company product range

----------------------Ruichang Mingsheng Automation Equipment Co., Ltd----------------------

PLC module, programmable controller, CPU module, IO module, DO module, AI module, DI module

Network communication module,

Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output

Module, redundancy module, power module, relay output module, relay input module, processor module


Obtain the latest price of GE DS200TCCAG2B Gas turbine card