Home > Product > Gas turbine system > GE DS200PTCTG1A Electronic module of gas turbine

  • GE DS200PTCTG1A Electronic module of gas turbine
GE DS200PTCTG1A Electronic module of gas turbine

GE DS200PTCTG1A Electronic module of gas turbine

GE DS200PTCTG1A Electronic module of gas turbine

LonBuilder Developer’s Workbench The process of creating programs for the twisted pair control modules requires attention to two main elements of a LonBuilder project definition. These elements include both the Channel definition and Hardware Property definition, and are considered in the following sections With the exception of the TP-RS485 module, the communications rate parameter must not be altered. It is also important to note the control modules do not support collision detection.

Channel Definition

 Channel setup requires consideration of both hardware and software issues. For software configuration, the LonBuilder tool configures the Neuron Chip communications port according to the channel definition accessed by selecting the Network and Channel buttons in the LonBuilder Navigator. Create a channel definition to use the Std Xcvr Type which matches the control module you wish to target. Always set the option Enforce Std Type to Yes unless you are making a decision to create devices which are not interoperable. For devices that do not need to meet the LONMARK interoperability guidelines, parameters associated with the number of priority slots, minimum clock rate, and oscillator accuracy may be adjusted for specific applications, but all other parameters must remain unchanged.

The TP/FT-10 channel has special requirements

 associated with devices which communicate with more than one physical layer repeater in the transmission path. These issues are discussed in both FTT-10 and FTT-10A user’s guides15,16. The hardware associated with the physical connection of the LonBuilder hardware to the targeted twisted pair media is an important development time consideration which includes several options. Table 9 lists the options available for connecting LonBuilder processor cards to the twisted pair network.It is important to set the backplane transceiver jumpers on the LonBuilder processor card to the External Transceiver setting prior to installing the SMX adapter.

                                        

 Company product range

----------------------Ruichang Mingsheng Automation Equipment Co., Ltd----------------------

PLC module, programmable controller, CPU module, IO module, DO module, AI module, DI module

Network communication module,

Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output

Module, redundancy module, power module, relay output module, relay input module, processor module


Obtain the latest price of GE DS200PTCTG1A Electronic module of gas turbine