Home > Product > Gas turbine system > GE DS200PTCTG1B Electronic module of gas turbine

  • GE DS200PTCTG1B Electronic module of gas turbine
GE DS200PTCTG1B Electronic module of gas turbine

GE DS200PTCTG1B Electronic module of gas turbine

GE DS200PTCTG1B Electronic module of gas turbine

One common LonBuilder configuration includes a LonBuilder Router (Echelon Model number 75400) which connects the LonBuilder backplane channel to the desired twisted pair media using one of the LonBuilder twisted pair transceivers described in table 9. When changing the LonBuilder hardware configuration to attach a LonBuilder router to an external twisted pair channel, ensure that the following steps are completed. 1 Select a backplane channel for side A and the desired twisted pair channel for side B in the LonBuilder Router Target HW definition. 2 Ensure that channel A of the router is connected to the backplane channel. For level 1 and 2 routers, a backplane transceiver must be installed in the router P2 channel A transceiver expansion connector. For level 3 routers, JP1 must be in the "B" position.

Mount a compatible LonBuilder

 twisted pair transceiver on the side "B" expansion connector. For level 3 routers, JP2 must be in the "A" position. 4 Create a router Target HW and Node Spec for the LonBuilder Router. In all cases, the Clock Rate field for the Target HW definition must be 10MHz. 5 Use the LonBuilder tool to install and load/start the router. A heavily loaded twisted pair channel may generate more traffic than can be forwarded through the LonBuilder Router. This may cause the LonBuilder Protocol Analyzer to miss some of the packets on the channel. To prevent lost packets, attach the protocol analyzer directly to the twisted pair channel.

This requires an additional transceiver 

as listed in table 9. When changing the LonBuilder hardware configuration to attach the protocol analyzer to the twisted pair channel, ensure that the following steps are completed

1 Select the desired twisted pair channel in the protocol analyzer Target HW definition. 

2 Mount a compatible LonBuilder twisted pair transceiver on the control processor's P3 expansion connector. For level 

3 control processors, JP1 must be in the "A" position. 3 Use the LonBuilder software to install the protocol analyzer.

                                        

 Company product range

----------------------Ruichang Mingsheng Automation Equipment Co., Ltd----------------------

PLC module, programmable controller, CPU module, IO module, DO module, AI module, DI module

Network communication module,

Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output

Module, redundancy module, power module, relay output module, relay input module, processor module


Obtain the latest price of GE DS200PTCTG1B Electronic module of gas turbine