Home > Product > Gas turbine system > GE DS200LRPAG2AGF Industrial electronic module

  • GE DS200LRPAG2AGF Industrial electronic module
GE DS200LRPAG2AGF Industrial electronic module

GE DS200LRPAG2AGF Industrial electronic module

GE DS200LRPAG2AGF Industrial electronic module

When turning off the drive controller with a absolute encoder (multiturn), the actual feedback position will be stored. When powered up, the absolute position given by the encoder is compared to the stored position. If the deviation is larger than the paramaterized "P-0-0097, AbsoluteEncoderMonitoring Window", the error "F276, Absolute Encoder Error" will appear and be given to the control system. Cause: 1. Turning on for the first time (invalid stored position). 2. The motor was moved further than allowed by the parameter in the absolute encoder monitoring window, P-0-0097, while it was turned off. 3. Incorrect position initialization

Remedy

 For 1. Press S1 to reset the error and set the absolute position. For 2. The motor was moved while turned off and sits outside of its permissible position. Check to see if the displayed position is correct in relation to the machine zero point. Reset subsequent errors. For 3. An accident may occur by accidental shaft movement. Check absolute position informartion. A feedback defect is present if the absolute position information is false. The motor should be exchanged and sent to the INDRAMAT Customer Service .

F629 Positive Travel Limit Value is Exceeded 

The drive has been provided with a command value that leads to an axis position outside the positive travel range. The axis has been stopped and the error reaction "set velocity command value to zero" issued. Bit 2 of P0-0090, Travel limit parameter has been set to "Exceeding the travel limit is an error", or a drive control command has been started while the axis limit value is exceeded (e.g. drive-controlled homing). Cause: S-0-0049, Positive position limit value is exceeded. Remedial action: 1. Check S-0-0049, Positive position limit value 2. Check the controller software limits 3. Activate the axis after the error reaction

                                        

Common problem

We have this product in stock, and we can deliver it to you at any time when you need it badly.

*The warranty period of all products is 1 year, which has passed the professional test certification.

*If you need to order more than one product, please contact us, and we can offer you a discount.

*We only use HDL  UPS  and other express delivery methods to deliver spare parts.

*If you find that other suppliers offer lower prices for the same products, we are also willing to offer you further discounts based on their prices.

If you have any other questions, please feel free to contact us via email.

*Please let us know if you need any spare parts, we can give you further assistance, and we are waiting for your inquiry.

Obtain the latest price of GE DS200LRPAG2AGF Industrial electronic module