Home > Product > Gas turbine system > GE DS200DTBCG1A Input expansion card

  • GE DS200DTBCG1A Input expansion card
GE DS200DTBCG1A Input expansion card

GE DS200DTBCG1A Input expansion card

GE DS200DTBCG1A Input expansion card

Parameter storage activ Description: A storage procedure is running in the drive as long as this warning is displayed. This means that the drive may not yet be switched off. Note: Wait until warning E209 fades before switching power off. If power is switched off while the warning stands, then the parameters could be lost or some parameters could become invalid.Note that the currently effective acceleration in the position command value is equal to zero. This is possible, for example, if the selected positioning block has a parametrized acceleration of a=0. Remedy: Enter a sensible accel value >0.

Positioning vel. (S-0-0259) greater S-0-0091 

Cause: For modes "drive-internal interpolation" and the "block-controlled mode", a speed must be entered in parameter S-0-0259, Positioning speed must be entered with which the target position can be reached. If this exceeds permissible maximum value S-0-0091, bipolar speed limit value, then message E249 is generated. Remedy: S-0-0259, Positioning speed or S-0-4007, process block speed must be reduced

For 1. If the blower fails exchange the drive controller. For 2. Install climitization feature to the cabinet. For 3. Check the dimensions of the control cabinet.

Heatsink Overtemperature Warning 

The temperature of the heatsink in the drive controller has reached the maximum allowable temperature. Within a time frame of 30 seconds, the drive follows the command value input. Consequently, there exists the possibility to shut down the motor with the control so that it remains true to the process. (For example close the operation, leave the collision area, etc.) After 30 seconds, the parameter "Best Possible Deceleration, P-0- 0119" set reaction appears during operation. Cause: 1. Deficiency of the drive's internal blower. 2. Deficiency of the control cabinet’s climate control. 3. Incorrect control cabinet dimensioning regarding the head ventilation.

                                        

Common problem

We have this product in stock, and we can deliver it to you at any time when you need it badly.

*The warranty period of all products is 1 year, which has passed the professional test certification.

*If you need to order more than one product, please contact us, and we can offer you a discount.

*We only use HDL  UPS  and other express delivery methods to deliver spare parts.

*If you find that other suppliers offer lower prices for the same products, we are also willing to offer you further discounts based on their prices.

If you have any other questions, please feel free to contact us via email.

*Please let us know if you need any spare parts, we can give you further assistance, and we are waiting for your inquiry.

Obtain the latest price of GE DS200DTBCG1A Input expansion card