Home > Product > Gas turbine system > GE DS200EXPSG1A Industrial electronic card

  • GE DS200EXPSG1A Industrial electronic card
GE DS200EXPSG1A Industrial electronic card

GE DS200EXPSG1A Industrial electronic card

GE DS200EXPSG1A Industrial electronic card

Overvoltage Error Cause: 1. The mechanical system energy reflected via the motor was so large for a moment that it could not be completely converted to heat by the bleeder. As a result, the DC Bus voltage rose above the maximum allowable value. The motor is then switched to torque free operation. If the DC Bus voltage falls below the maximum allowable value, the controller will be turned on again. 2. DC Bus voltage is too high The drive has received a command value that has led to an axis position outside the positive travel range. The axis is stopped by setting the velocity command value to zero. A class 1 diagnostics error is not generated. The drive automatically follows command values that lead back to the valid range. Bit 2 of S-0-0090, Command Value Transmit Time (TMTSG) has been set to "Exceeding the travel limit is considered as a warning".

E830 Negative Position Limit Value Exceeded 

The drive has received a command value that has led to an axis position outside the negative travel range. The axis is stopped by setting the velocity command value to zero. A class 1 diagnostics error is not generated. The drive automatically follows command values that lead back to the valid range. Bit 2 of S-0-0090, Command Value Transmit Time (TMTSG) has been set to "Exceeding the travel limit is considered as a warning". Cause: S-0-0050, Negative position limit value exceeded. Remedial action: Specify command values that lead back to the valid range.

Jog Position Limit Value Exceeded

 Description: If the position limit value monitor is activated and the drive is “IN REFERENCE", then it will be positioned during movement in the jogging operation on the position limit value. If the drive is positioned on the position limit value or on the other side of the position limit value, then the drive stays still and signals „"position limit value reached during jogging." Remedy: 1. Move the motor back within the allowable travel area with the jog function. 2. Turn off the position limit value monitor

                                        

Common problem

We have this product in stock, and we can deliver it to you at any time when you need it badly.

*The warranty period of all products is 1 year, which has passed the professional test certification.

*If you need to order more than one product, please contact us, and we can offer you a discount.

*We only use HDL  UPS  and other express delivery methods to deliver spare parts.

*If you find that other suppliers offer lower prices for the same products, we are also willing to offer you further discounts based on their prices.

If you have any other questions, please feel free to contact us via email.

*Please let us know if you need any spare parts, we can give you further assistance, and we are waiting for your inquiry.

Obtain the latest price of GE DS200EXPSG1A Industrial electronic card