Home > Product > Robot control system > AUTOMATIONX AXLINK100 892.202988 module

  • AUTOMATIONX AXLINK100 892.202988 module
  • AUTOMATIONX AXLINK100 892.202988 module
  • AUTOMATIONX AXLINK100 892.202988 module
AUTOMATIONX AXLINK100 892.202988 module AUTOMATIONX AXLINK100 892.202988 module AUTOMATIONX AXLINK100 892.202988 module

AUTOMATIONX AXLINK100 892.202988 module

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

AUTOMATIONX AXLINK100 892.202988 module

3Φ/AΦ/BΦ/CΦ kW MIN/MAX: The minimum/maximum three phase real power as well as the minimum/maximum individual phase A/B/C real power is displayed, along with the time and date of their measurement. This information is stored in non-volatile memory and will be retained during a loss of control power. The phase A/B/C minimum/maximum real power messages will be displayed only for a “Wye” connected system. • 3Φ/AΦ/BΦ/CΦ kvar MIN/MAX: The minimum/maximum three phase reactive power as well as the minimum/maximum individual phase A/B/C reactive power is displayed, along with the time and date of their measurement. This information is stored in nonvolatile memory and will be retained during a loss of control power. The phase A/B/C minimum/maximum reactive power messages will be displayed only for a “Wye” connected system.

The minimum/maximum three phase apparent power as well as the minimum/maximum individual phase A/B/C apparent power is displayed, along with the time and date of their measurement. This information is stored in non-volatile memory and will be retained during a loss of control power. The phase A/B/C minimum/maximum apparent power messages will be displayed only for a “Wye” connected system

Energy metering actual values are displayed here. 

The S1 PQMII SETUP ÖØ CLEAR DATA ÖØ CLEAR ENERGY VALUES setpoint clears these values. The displayed energy values roll over to “0” once the value “4294967295” (FFFFFFFFh) has been reached. • 3Φ POS/NEG REAL ENERGY: These messages display the positive/negative watthours (in kWh) since the TIME OF LAST RESET date. Real power in the positive direction add to the 3Φ POS REAL ENERGY value, whereas real power in the negative direction adds to the 3Φ NEG REAL ENERGY value. • 3Φ POS/NEG REACT ENERGY: These messages display the positive/negative varhours (in kvarh) since the TIME OF LAST RESET date. Reactive power in the positive direction add to the 3Φ POS REACT ENERGY value, whereas reactive power in the negative direction adds to the 3Φ NEG REACT ENERGY value. • 3Φ APPARENT ENERGY: This message displays the accumulated VAhours (in kVAh) since the TIME OF LAST RESET date. • REAL ENERGY LAST 24h: This message displays the accumulated real energy (in kWh) over the last 24-hour period. The 24-hour period used by the PQMII is started when control power is applied. The PQMII updates this value every hour based on the previous 24-hour period. This information will be lost if control power to the PQMII is removed.

Obtain the latest price of AUTOMATIONX AXLINK100 892.202988 module