Home > Product > DCS control system > HONEYWELL CC-PAIX01 Sequence control module

  • HONEYWELL CC-PAIX01 Sequence control module
  • HONEYWELL CC-PAIX01 Sequence control module
  • HONEYWELL CC-PAIX01 Sequence control module
HONEYWELL CC-PAIX01 Sequence control module HONEYWELL CC-PAIX01 Sequence control module HONEYWELL CC-PAIX01 Sequence control module

HONEYWELL CC-PAIX01 Sequence control module

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

HONEYWELL CC-PAIX01 Sequence control module

REAL ENERGY COST: This message displays the total cost for the real energy accumulated since the TIME OF LAST RESET date. • REAL ENERGY COST PER DAY: Displays the average cost of real energy per day from time of last reset to the present. The cost per kWh is entered in the S1 PQMII SETUP ÖØ CALCULATION PARAMETERS ÖØ ENERGY COST PER KWH setpoint. • TARIFF PERIOD 1(3) COST: These messages display the cost accrued for the three user-definable tariff periods. The start time and cost per kWh for these tariff periods are entered with the S1 PQMII SETUP ÖØ CALCULATION PARAMETERS ÖØ TARIFF PERIOD 1(3) START TIME and the S1 PQMII SETUP ÖØ CALCULATION PARAMETERS ÖØ TARIFF PERIOD 1(3) COST PER KWH setpoints, respectively. • TARIFF PERIOD 1(3) NET ENERGY: These messages display the net energy for the three user-definable tariff periods. The start time and cost per kWh for these tariff periods are entered with the S1 PQMII SETUP ÖØ CALCULATION PARAMETERS ÖØ TARIFF PERIOD 1(3) START TIME and the S1 PQMII SETUP ÖØ CALCULATION PARAMETERS ÖØ TARIFF PERIOD 1(3) COST PER KWH setpoints, respectively. • TIME OF LAST RESET: This message displays the time and date when the energy parameters were last cleared through the S1 PQMII SETUP ÖØ CLEAR DATA ÖØ CLEAR ENERGY VALUES setpoint

PHASE A/B/C/NEUTRAL DEMAND

This message displays the phase A/B/C/N current demand (in amps) over the most recent time interval. • 3Φ REAL POWER DEMAND: This message displays the 3 phase real power demand (in kW) over the most recent time interval. • 3Φ REACTIVE POWER DEMAND: This message displays the 3 phase reactive power demand (in kvar) over the most recent time interval. • 3Φ APPARENT POWER DEMAND: This message displays the 3 phase apparent power demand (in kVA) over the most recent time interval. • Ia/Ib/Ic/In MAX DMD: These messages display the maximum phase A/B/C/N current demand (in amps) and the time and date when this occurred. • 3Φ kW MAX: This message displays the maximum three-phase real power demand (in kW) and the time and date when this occurred. • 3Φ kvar MAX: This message displays the maximum three-phase reactive power demand (in kvar) and the time and date when this occurred. • 3Φ kVA MAX: This message displays the maximum three-phase apparent power demand (in kVA) and the time and date when this occurred.

Obtain the latest price of HONEYWELL CC-PAIX01 Sequence control module