Ethernet – 10Base2 10Base2 Ethernet is a linear network with nodes fitted along the length of one network; it cannot cope with spurs. The connections use 50 Ω coax cables (e.g. RG58). The rules for connecting 10Base2 Ethernet are given below. • The maximum length of a segment without repeaters is 185 m. • A maximum of 4 repeaters are allowed to extend a segment, where the cable length between the repeaters is less than or equal to that of a non-repeated cable segment and 2 segments must be links only (i.e. no connections apart from the 2 repeaters)
Cable Wiring for RS485
Notes: Labels are shown the same as those on the Product Descriptions. RX/TX = Receive circuit in 4 wire applications. Multiplexed circuit for 2 wire applications. GND = Signal Ground. There are actually 2 identical connectors on the Interface Adapter for each port. This is to allow either side of multi-drop connections to be connected to separate connectors. No ‘To’ connections have been shown as there is no standard connector for RS485 and many devices have terminal blocks for the connections.
• The maximum number of nodes
on a segment is 30 and includes any repeaters. • There should be a minimum of 0.5 m between nodes. • Each cable segment must be terminated at either end with a 50 Ω termination. • The connections to each device must be by T-connectors directly onto the BNC jack provided. A spur from the network to the device will cause reflections in the cabling and stop the network working correctly. • The screen of a segment may be earthed for safety reasons if required, but only at one point on the segment.
Our superior products
ABB -- AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHEO0 3HNA00 DSOC series
BENTLY --- 3500 system/proximitor, front and rear cards, sensors, power modules, probes, cables
Emerson -- modbus card, power panel, controller, power supply, base, power module, switch
EPRO --- Data acquisition module, probe, speed sensor, vibration sensor, shaft vibration transmitter, proximitor
FOXBORO - thermal resistance input/output module, power module, communication module, cable, controller, switch
GE --- module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA --- DI module, processor module, AI card, pulse encoder
Honeywell --- Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG - servo valve, controller, module, power module
NI --- Information acquisition card, PXI module, card, chassis multi-channel control card
WESTINGHOUSE --- RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward - Regulator, module, controller, governor
YOKOGAWA - Servo module, control cabinet node unit