Home > Product > DCS control system > ABB DSPC 157 Communication card

  • ABB DSPC 157 Communication card
ABB DSPC 157 Communication card

ABB DSPC 157 Communication card

ABB DSPC 157 Communication card

It is also possible to overload the CIs by using too fast a poll rate on the OPC server. The poll variables are divided into two groups: those that have SOE or Process Historian enabled (Sequence of Events Update and Process Historian Update), and the Modbus data that does not have SOE (Global Ungrouped Tag Update). The product description for the OPC Server describes loading and timing calculations. An Ethernet link should be designed to be less than 30 % loaded.For CIs before release 3.5, allow about 3 ms per Modbus / data packet for the OPC server if the CI is not running peer to peer. If the CI is running peer to peer, allow about 6 ms per OPC packet. The non SOE Modbus data may have several packets, each update depending how the Modbus variables are distributed. Sequential Modbus addresses are the most efficient.

Interface Adapter Connectors 

Table 24 below gives a list of connectors required to interface to the CI Interface Adapter (T8153). The network statistics are available by typing 'tcp ns' on the CI diagnostic (see section 5). By waiting 10 seconds and requesting another reading it is possible to work out how many packets are passing over a 10 second period and hence the time per packet. The situation can be made worse if there are a lot of writes to the system, because they are individually passed to the Processor and can take longer.

SOE Over Modbus Protocol 

The SOE Over Modbus Protocol is defined in two parts: the definition of the Modbus registers within the SOE Address Window, and the defined interaction between the Modbus Master and the SOE over Modbus service. 7.1. SOE Address Window The SOE Over Modbus protocol operates over the Modbus addresses within the configured SOE Address Window. Modbus operations on address within this window are used exclusively for the protocol. The SOE Over Modbus service defines registers within the address space required for the operation of the protocol. Each register is accessed in the normal manner

                                        

Our superior products

ABB -- AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHEO0 3HNA00 DSOC series

BENTLY --- 3500 system/proximitor, front and rear cards, sensors, power modules, probes, cables

Emerson -- modbus card, power panel, controller, power supply, base, power module, switch

EPRO --- Data acquisition module, probe, speed sensor, vibration sensor, shaft vibration transmitter, proximitor

FOXBORO - thermal resistance input/output module, power module, communication module, cable, controller, switch

GE --- module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card

HIMA --- DI module, processor module, AI card, pulse encoder

Honeywell --- Secure digital output card, program module, analog input card, CPU module, FIM card

MOOG - servo valve, controller, module, power module

NI --- Information acquisition card, PXI module, card, chassis multi-channel control card

WESTINGHOUSE --- RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module

Woodward - Regulator, module, controller, governor

YOKOGAWA - Servo module, control cabinet node unit


Obtain the latest price of ABB DSPC 157 Communication card