  • ABB DSAV 111 57350001-CN Logic control card
ABB DSAV 111 57350001-CN Logic control card

ABB DSAV 111 57350001-CN Logic control card

ABB DSAV 111 57350001-CN Logic control card

Enter the Name, Description and Slot options for your application. You must select the Comm Format as DATA - INT in the dialog box, otherwise the module will not communicate. Click OK to continue.Select the Requested Packet Interval value for scanning the I/O on the module. This value represents the minimum frequency that the module will handle scheduled events. This value should not be set to less than 1 millisecond. The default value is 5 milliseconds. Values between 1 and 10 milliseconds should work with most applications.Save the module. Click OK to dismiss the dialog box. The Controller Organization window now displays the module's presence.Copy the User-Defined Data Types from the sample program into your existing RSLogix 5000 project. 7 Copy the Controller Tags from the sample program into your project. 8 Copy the Ladder Rungs from the sample program into your project.

Diagnostics and Troubleshooting

The module provides information on diagnostics and troubleshooting in the following forms:  LED status indicators on the front of the module provide general information on the module's status.  Status data contained in the module can be viewed through the Configuration/Debug port, using the troubleshooting and diagnostic capabilities of ProSoft Configuration Builder (PCB).  Status data values can be transferred from the module to processor memory and can be monitored there manually or by customer-created logic.Data is being transferred between the module and a remote terminal using the Configuration/Debug port.The MVI56-EGD module program has recognized a communication error on one of its ports.

The card is not receiving any power 

 is not securely plugged into the rack. Green The module is operating normally. Red The program has detected an error or is being configured. If the LED remains red for over 10 seconds, the program has probably halted. Remove the card from the rack and re-insert the card to restart the module’s program. BATT Red Off The battery voltage is OK and functioning. On The battery voltage is low or battery is not present. Allow battery to charge by keeping module plugged into rack for 24 hours. If BAT LED still does not go off, contact ProSoft Technology, as this is not a user serviceable item. If the APP, BP ACT and OK LEDs blink at a rate of every one-second, call ProSoft Technology support. There is a serious problem with the module, and it will have to be sent back to ProSoft.

                                        

Quality assurance service

1. We provide high-quality parts of various brands, and you will find full

The model meets your needs.

2. For models that have been out of production for many years, we have all hard to find parts, so we can directly find us to solve all problems for you at one time.

3. If you are in a hurry to use this product, we can dispatch it for you.

4. All products can enjoy a one-year warranty service,

5. Our products are new and unused.

6. If you need a large quantity, you can contact us and I can offer you a discount.

7. You can ask me about the price and more information about the product via email. We welcome you

Obtain the latest price of ABB DSAV 111 57350001-CN Logic control card