The following table defines the contents of the configuration error word. Each bit in the word corresponds to an error condition recognized when the module is configured. There is a separate word for each application port. This data is reported in the status data area previously defined. In addition, the full specification of a system may require individual selection of certain parameters for certain parts of the system, such as the individual selection of scaling factors for individually addressable measured values. The selected parameters should be marked in the white boxes as follows: Function or ASDU is not used ⌧ Function or ASDU is used as standardized (default) R Function or ASDU is used in reverse mode B Function or ASDU is used in standard and reverse mode The possible selection (blank, X, R, B) is specified for each specific clause or parameter. A black check box indicates that the option cannot be selected in this companion standard.
Protocol Interoperability Documentation
This companion standard presents sets of parameters and alternatives from which subsets have to be selected to implement particular telecontrol systems. Certain parameter values, such as the number of octets in the COMMON ADDRESS of ASDUs represent mutually exclusive alternatives. This means that only one value of the defined parameters is admitted per system. Other parameters, such as the listed set of different process information in command and in monitor direction allow the specification of the complete set or subsets, as appropriate for given applications. This clause summarizes the parameters of the previous clauses to facilitate a suitable selection for a specific application. If a system is composed of equipment stemming from different manufacturers it is necessary that all partners agree on the selected parameters.
Before calling for support
please prepare yourself for the call. In order to provide the best and quickest support possible, we will most likely ask for the following information: 1 Product Version Number 2 System architecture 3 Module configuration and contents of configuration file 4 Module Operation o Configuration/Debug status information o LED patterns 5 Information about the processor and user data files as viewed through the processor configuration software and LED patterns on the processor 6 Details about the serial devices interfaced An after-hours answering system allows pager access to one of our qualified technical and/or application support engineers at any time to answer the questions that are important to you.
Brand display
ABB、GE/FUANC、FOXBORO、TRICONEX 、BENTLY、A-B、EMERSON 、MOTOROLA、XYVOM、HONEYWELL 、REXROTH、KUKA、NI、DEIF、Yokogawa、WOODWARD、Reliance Electric、SCHNEIDER 、MOOG、PROSOFT、KOLLMORGEN、ICS TRIPLEX、HIMA。