Home > Product > DCS control system > ABB 3BSE016239R1 PM510V08 Pulse accumulator module

  • ABB 3BSE016239R1 PM510V08 Pulse accumulator module
ABB 3BSE016239R1 PM510V08 Pulse accumulator module

ABB 3BSE016239R1 PM510V08 Pulse accumulator module

ABB 3BSE016239R1 PM510V08 Pulse accumulator module

This section defines Session y, which runs on Port x.The Session Count parameter in the [IEC-870-5-101 Master] section of the configuration (page 42) determines the number of sessions (controlled devices) for this port. The sessions are referenced by a zero-based index value. For example, if the module is configured for four sessions, the configuration file should contain sections for Sessions 0 to 3 (that is, [IEC-101 Master Session 0] to [IEC-101 Master Session 3]). The parameters in [IEC-101 Master Session y] define the characteristics of the specific controlled device to interface.This parameter sets the port to which the controlled device is connected. On this module, values of 0 and 1 are permitted.

Sector Count

This parameter sets the number of sectors contained in this controlled device. The range of values is from 1 to 5. A sector section is required for each sector in a session to define its database and settings. 2.6.3 Data Link Address 0 to 254 or 0 to 65534 This parameter uniquely defines the data link address for this unit on the communication channel The ranges of values depends on the value set in the DL Address Length parameter. 2.6.4 Common address of ASDU Len 1 or 2 This parameter specifies the number of octets used for the common address of ASDU. This parameter must be set the same for all devices on the network. 2.6.5 Inform. Object address Len 1, 2 or 3 This parameter sets the number of octets used to specify the address for an information object in each sector for this session

COT octet count

This parameter sets the number of octets used for the COT field in each message. If a value of 2 is selected, the value entered for the Originator Address For COT will accompany each message from the controlling unit. 2.6.7 Originator address for COT 0 to 255 This parameter sets the address to be passed with each message when the COT Octet Count parameter is set to 2. 2.6.8 Failure Delay 0 to 2000 seconds This parameter sets the minimum number of seconds to delay before polling this session when it is not online. This parameter is only used in unbalanced mode.

                                        

 Brand display

 ABBGE/FUANCFOXBOROTRICONEX BENTLYA-BEMERSON MOTOROLAXYVOMHONEYWELL REXROTHKUKANIDEIFYokogawaWOODWARDReliance ElectricSCHNEIDER MOOGPROSOFTKOLLMORGENICS TRIPLEXHIMA。

Obtain the latest price of ABB 3BSE016239R1 PM510V08 Pulse accumulator module