Home > Product > DCS control system > ABB CI630 3BSE011000R1 Line interface module

  • ABB CI630 3BSE011000R1 Line interface module
ABB CI630 3BSE011000R1 Line interface module

ABB CI630 3BSE011000R1 Line interface module

ABB CI630 3BSE011000R1 Line interface module

Stopping the Data Analyzer Press [S] to stop the data analyzer. Use this option to freeze the display so the data can be analyzed. To restart the analyzer, press [B]. Important: When in analyzer mode, program execution will slow down. Only use this tool during a troubleshooting session. Before disconnecting from the Config/Debug port, please press [S] to stop the data analyzer, and then press [M] to return to the main menu. This action will allow the module to resume its normal high speed operating mode.

Data Analyzer Tips From the main menu, press [A] for the "Data Analyzer". You should see the following text appear on the screen: After the "Data Analyzer" mode has been selected, press [?] to view the Data Analyzer menu.

From this menu, you can select the "Port"

 the "format", and the "ticks" that you can display the data in. For most applications, HEX is the best format to view the data, and this does include ASCII based messages (because some characters will not display on HyperTerminal and by capturing the data in HEX, we can figure out what the corresponding ASCII characters are supposed to be). The Tick value is a timing mark. The module will print a _TT for every xx milliseconds of no data on the line. Usually 10milliseconds is the best value to start with. After you have selected the Port, Format, and Tick, we are now ready to start a capture of this data. The easiest way to do so is to go up to the top of you HyperTerminal window

Next name the file

 and select a directory to store the file in. In this example, we are creating a file ProSoft.txt and storing this file on our root C: drive. After you have done this, press the button. Now you have everything that shows up on the HyperTerminal screen being logged to a file called ProSoft.txt. This is the file that you will then be able to email to ProSoft Technical Support to assist with issues on the communications network. To begin the display of the communications data, you will then want to press [B] to tell the module to start printing the communications traffic out on the debug port of the module.


                                        

 Brand display

 ABBGE/FUANCFOXBOROTRICONEX BENTLYA-BEMERSON MOTOROLAXYVOMHONEYWELL REXROTHKUKANIDEIFYokogawaWOODWARDReliance ElectricSCHNEIDER MOOGPROSOFTKOLLMORGENICS TRIPLEXHIMA。

Obtain the latest price of ABB CI630 3BSE011000R1 Line interface module