Home > Product > DCS control system > ABB CI670 3BHT300017R1 AC power module

  • ABB CI670 3BHT300017R1 AC power module
ABB CI670 3BHT300017R1 AC power module

ABB CI670 3BHT300017R1 AC power module

ABB CI670 3BHT300017R1 AC power module

Press [D] from the Sector Configuration menu to open the Sector Database menu. Use this command to display the sector database values. Each session (controlled device) contains one or more data sets (sectors) that are defined by the vendor of the device.The program has detected an error or is being configured. If the LED remains red for over 10 seconds, the program has probably halted. Remove the card from the rack and re-insert the card to restart the module’s program.The battery voltage is low or battery is not present. Allow battery to charge by keeping module plugged into rack for 24 hours. If BAT LED still does not go off, contact ProSoft Technology, as this is not a user serviceable item.

Clearing a Fault Condition 

Typically, if the OK LED on the front of the module turns RED for more than ten seconds, a hardware problem has been detected in the module or the program has exited. To clear the condition, follow these steps: 1 Turn off power to the rack. 2 Remove the card from the rack. 3 Verify that all jumpers are set correctly. 4 If the module requires a Compact Flash card, verify that the card is installed correctly. 5 Re-insert the card in the rack and turn the power back on. 6 Verify correct configuration data is being transferred to the module from the SLC controller. If the module's OK LED does not turn GREEN, verify that the module is inserted completely into the rack. If this does not cure the problem, contact ProSoft Technology Technical Support.

Troubleshooting

 Use the following troubleshooting steps if you encounter problems when the module is powered up. If these steps do not resolve your problem, please contact ProSoft Technology Technical Support.Verify that the module is plugged into the slot that has been configured for the module in the I/O Configuration of RSLogix. Verify that the slot location in the rack has been configured correctly in the ladder logic.This indicates a problem with backplane communications. A problem could exist between the processor and any installed I/O module, not just the MVI46-101M. Verify that all modules in the rack are correctly configured in the ladder logic.

                                        

 Brand display

 ABBGE/FUANCFOXBOROTRICONEX BENTLYA-BEMERSON MOTOROLAXYVOMHONEYWELL REXROTHKUKANIDEIFYokogawaWOODWARDReliance ElectricSCHNEIDER MOOGPROSOFTKOLLMORGENICS TRIPLEXHIMA。

Obtain the latest price of ABB CI670 3BHT300017R1 AC power module