Home > Product > DCS control system > ABB CS512 3BUR980009R1 Thermocouple module

  • ABB CS512 3BUR980009R1 Thermocouple module
ABB CS512 3BUR980009R1 Thermocouple module

ABB CS512 3BUR980009R1 Thermocouple module

ABB CS512 3BUR980009R1 Thermocouple module

This field contains the session index used to define the controlled unit in the module from which the event was generated. 1 Sector Index This field contains the sector index used to define the database within the controlled unit from which the event was generated. 2 COT This field contains the COT for the event message received from the IED. If the size of the COT is a single byte, the originator address will always be zero. The COT is in the LSB and the originator address is in the MSB. 3 Reserved This field is reserved for future use and is added here to keep the structure double-word aligned for all platforms.This field contains the ASDU type code for the data contained in the message.This field contains the minutes and hours the event occurred.

In order for this feature to be activated,

 the event pass-through parameter must be set. When a master driver receives an event message from a controlled station, it will build an event message corresponding to the event in the event buffer of the module. This buffer is then sent to the processor when any messages are present. Therefore, these blocks are sent to the processor on a high priority. After the block is sent, the event message is removed from the module’s event buffer. The ladder logic should set register 4200 to a value of zero after processing the event message data. If too many events are present in the buffer (>200), the module will set the event message overflow flag in the error/status data area of the normal read data block. There is no response block to be received by the module from the processor.

Read Command Error List Block (9950)

 Block 9950 identification code requests the Command List Error Table from the module for the 1000 user configurable commands. The format for the block is shown in the following diagram:This field contains the value of 9950 identifying the block type to the module. 4101 Number of Commands to report This field contains the number of commands to report in the response message. The value has a range of 1 to 60. 4102 Start Index of First Command This parameter sets the index in the command list where to start. The first command in the list has a value of 0. The last index in the list has a value of MaxCommands - 1.

                                        

 Brand display

 ABBGE/FUANCFOXBOROTRICONEX BENTLYA-BEMERSON MOTOROLAXYVOMHONEYWELL REXROTHKUKANIDEIFYokogawaWOODWARDReliance ElectricSCHNEIDER MOOGPROSOFTKOLLMORGENICS TRIPLEXHIMA。

Obtain the latest price of ABB CS512 3BUR980009R1 Thermocouple module