 The ambient conditions stated must be observed. See Chapter 9.9 Ambient conditions, 

 62.  Sufficient ventilation (cooling) must be ensured by means of: 

 Clearance of at least 3 cm to the ventilation slots 

 Clearance of at least 15 cm from heat radiating components such as heavily loaded transformers 

 The expected temperatures should be within the permissible range. See Chapter 9.9 Ambient conditions,  62.  Properties of the mounting surfaces: 

 Material thickness at the mounting cutout 2…5 mm  Flatness  0.5 mm (this requirement must also be fulfilled when the device is mounted!)  Surface roughness Rz  120

Requirements for the mounting position 

The device is designed for mounting in control cabinets, control panels or control desks. 10.4" and 12.1" devices can be mounted horizontally or vertically, 15" devices must only be mounted horizontally. The following requirements must be fulfilled when selecting a suitable mounting position:  The device should not be exposed to direct sunlight (Sunlight disturbs the infra-red touch sensor. In addition, when exposed to UV light, plastic parts of the device can embrittle and the lifespan of the device is reduced).  If the device is to be used in potentially explosive atmospheres, the device must not be subjected to hazardous knocks.  The operating elements on the service side of the device and the cable connections are accessible after the device has been mounted.

Operational malfunctions 

Use of unsuitable or improperly prepared cables, as well as incorrect wiring will mean that neither the values stated in the technical data nor the electromagnetic compatibility (EMC) can be ensured. 

 Only use cables prepared by specialists. 

 The cables used must be prepared according to the interface description in this document. 

 The wiring instructions for the relevant interface must be observed when wiring the device. 

 Any generally applicable regulations and standards must be fulfilled.

                                          

Application industry