Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Unit for Optical ESB Bus Repeater Module Power Supply Modules, Optical ESB Bus Repeater Module are installed in a Unit. For more details, refer to “Unit for Optical Bus Repeater Module (for AFV30/AFV40)” (GS 33K50F50-50E)l I/O Modules The I/O Modules include Analog I/O Modules, Digital I/O Modules and Communication Modules. There are several types of Analog I/O Modules, including the isolated channel type, isolated type and non-isolated type. In addition, to enable replacements from CENTUM V, CENTUM-XL and µXL compatible modules are provided so that the system cable from the Signal Conditioner can be connected to these compatible modules. For the I/O Modules, the environment-proof support (temperature environment support, G3 support) options can be specified. The I/O Module is Explosion Protection product. For details, refer to “Explosion Protection” (TI 33Q01J30-01E).For detailed specifications of each I/O Module, refer to GS 33K50E50-50E, GS 33K50E51-50E, GS 33K50F40-50E, GS 33K50F51-50E, GS 33K50F52-50E, GS 33K50F60-50E, GS 33K50F70-50E, GS 33K50F90-50E, GS 33K50G10- 50E, GS 33K50G11-50E, GS33K50G20-50E, GS 33K50K80-50E. For detailed specifications of each I/O Module, refer to “I/O Modules With Built-In Barrier (for FIO)” (GS 33K50F80- 50E). When installing these apparatuses with intrinsically safe circuit, “Explosion Protection” (TI 33Q01J30-01E) and “Explosion Protection of FIO Products” (IM 33Y06K01-90E) for CENELEC Approval should be referenced together with this GS.
To wire between I/O Module and field devices, install a pressure clamp terminal or KS cable interface adapter on the I/O Module. When a pressure clamp terminal is used, the I/O Module can be wired directly with the field devices. When the KS cable interface adapter is used, the I/O Module is wired with the field devices via terminal boards. Two types of pressure clamp terminal blocks are available: single and dual-redundant types. Using the dual-redundant type, dual-redundant I/O Modules can be configured on the terminal block. In addition, a MIL connector cable can be connected directly to an I/O Module without installing a terminal block to the I/O Module. The MIL connector cable are furnished by the customer. A cable connector cover (ACCC01) is provided in order to prevent the MIL connector cable from coming loose.Please keep a distance of 50 mm or more between the intrinsically safe area and the non-intrinsically safe area. Modules with built-in barriers should be installed in an area separate from the area of other modules in one node unit. In case of AN10, an insulating partition (Part No. T9083NA) must be installed between the area of Modules with Built-in Barrier and the area of other Modules. In case of AFV10 and AFV30, an insulating partition kit (Part No. T9083ND) must be installed to keep a distance between the intrinsically safe area and the non-intrinsically safe area. Example: When isolating the two areas in an AN10D as follows where “(S)” indicates Single and “(D)” indicates Dual-Redundant.