Home > Product > PLC programmable module > BENTLY 3500/50 Monitor Module

  • BENTLY 3500/50 Monitor Module
BENTLY 3500/50 Monitor Module

BENTLY 3500/50 Monitor Module

BENTLY 3500/50 Monitor Module

TM essentially connects the current console serial port and the port specified in the command (default is the host port) together, allowing you to communicate with a host computer. A message displayed by TM shows the current escape character, i.e., the character used to exit the transparent mode. The two ports remain "connected" until the escape character is received by the console port. The escape character is not transmitted to the host, and at power-up or reset it is initialized to $01=^A. The ports do not have to be at the same baud rate, but the console port baud rate should be equal to or greater than the host port baud rate for reliable operation. To change the baud rate use the Port Format (PF) command. If the port number is omitted and the escape argument is entered as a numeric value, precede the escape argument with a comma to distinguish it from a port number.

TT - Trace to Temporary Breakpoint

TT sets a temporary breakpoint at the specified address and traces until a breakpoint with 0 count is encountered. The temporary breakpoint is then removed (TT is analogous to the GT command) and control is returned to 16XBug. Tracing starts at the target PC address. Breakpoints are monitored (but not inserted) during tracing for all trace commands. Instruction memory must be writable. If a breakpoint with 0 count is encountered, control is returned to 16XBug. The trace functions are implemented with the trace bits (T0, T1) in the MC68040 status register, and in the T-bit in the MC68060 status register. These bits should not be modified while using the trace commands.

VE - Verify S-Records Against Memory

The optional port number "port" allows you to specify which port is to be used for the downloading. If the port number is not specified but the address option is specified, VE must be separated from address by two commas. If this number is omitted, port 1 is assumed. address The optional address field allows you to enter an offset address which is to be added to the address contained in the address field of each record. This causes the records to be compared to memory at different locations than would normally occur. The contents of the automatic offset register are not added to the S-record addresses. (For information on S-records, refer to Appendix C.)

                                                      

product application

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on

Superior products

--ABB Accuray

--ABB Advant OCS

--ABB Advant-800xA

--ABB H&B Contrans T

--ABB H&B Freelance 2000

--Allen Bradley PLC

--GE Ran card machine accessories,PLC

--ICS Triplex Rockwell T8151B/T8461/T8310

--Triconex/Foxboro:3625/3721/3503E/FBM237/FBM242

--Emerson:CE3008/VE3008/SE3008/A6120/A6312

--Motorola:MCP750/MVME162/MVME2604/MVME5100

--Woodward:9907-164/9907-167/9905-144/9905-018

The company is mainly engaged in above brands. You are welcome to inquire from me via email!



Obtain the latest price of BENTLY 3500/50 Monitor Module