Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
The following rules generally apply with regard to the connection of Advant Fieldbus 100 to modems and modems: • Τhe shielding, when Coaxial or twisted pair cable is used, must be grounded. The shielding is grounded in one end only. • All cable shielding connections must be shorter than 50 mm (≈2”). For further information regarding cable shield grounding and installation, please refer to the manual Advant OCS Installation Rules. 4.3.4 Connection of optical modem NOTE The optical twin pair cable is installed between two optical modems. One of the two fibres in the cable shall be connected to the TX optical connector on the first optical modem and the RX connector on the second optical modem. The other fibre cable shall be connected in the opposite way, in the RX connector on the first optical modem and TX optical connector on the second optical modem.
The basic rules concerning Advant Fieldbus 100 terminations are as follows: • Coaxial segments of an Advant Fieldbus 100 must be terminated on both ends. • Τhe coaxial sections end points MUST be terminated with a 75 ohm BNC terminating plug.
When an Advant Controller 70 communication interface is started, its CDPs are be configured. As the communication interface can not be a Bus Administrator, its CDPs are configured on the Bus Administrator which currently is master. This is performed when the Advant Controller 70 is started and connected to the bus or when a Bus Administrator configured as master has started. At start up all LEDs on the Advant Controller 70 front are lit for about a second during the hardware init. The station is running when the R (RUN) indicator is lit.
Sufficient space should remain beneath the modem to permit a certain minimum bending radius of the cable (R in the figure above). This radius depends on the cable type and is normally 100 mm for apparatus cable and cable for indoor industrial environments. For underground and submarine cable, a radius equal to or greater than 200 mm (≈ 8”) is normally required. The manufacturer of the cable should be contacted in the event of uncertainty. Contact the optical cable manufacturer about info how to handle the optical cable during installation. The installation of optical connectors on the cable is a precision work which should be performed by specialists. The cable supplier can usually recommend such experts. The optical connectors are of the STx4 type. 4.4 Starting an Advant Controller 70 When the network has been installed, the Advant Controller 70 (PM810) can be started