Home > Product > DCS control system > ABB PFSK 102 YM322001-EG Pulse input module

  • ABB PFSK 102 YM322001-EG Pulse input module
ABB PFSK 102 YM322001-EG Pulse input module

ABB PFSK 102 YM322001-EG Pulse input module

ABB PFSK 102 YM322001-EG Pulse input module

The display format of the position data can be set with the help of the scaling parameter. The internal drive format of the position data is dependent on the applied feedback and the controller resolution. The factor for the conversion of the position data from the internal drive format into the display format or the reverse conversion is outside of the workable area because either: • Rotary motor and linear positional scaling are not representable or • the average factor for conversion of the position data from the display format into the internal format (or reverse process) is not representable. Remedy: Connect the drive with a PC and start DriveTop. In the dialog box „Scaling/Mechanical system" select a scaling setting. Should another scaling installation other than one from DriveTop be used, then the following parameters must be checked.

Velocity Data Scaling Error 

 The display format of the velocity data can be set with the help of the scaling parameter. The internal drive format of the velocity data is dependent on the applied feedback and the controller resolution. The factor for the conversion of the velocity data from the internal drive format into the display format (or the reverse process) is outside of the workable area. Remedy: Connect the drive with a PC and start DriveTop. In the dialog box „Scaling/Mechanical system" select a scaling setting. Should another scaling installation other than one from DriveTop be used, then the following parameters must be checked.

Acceleration Data Scaling Error 

The display format of the acceleration data can be set with the help of the scaling parameter. The internal drive format of the acceleration data is dependent on the applied feedback and the controller resolution. The factor for the conversion of the acceleration data from the internal drive format into the display format (or the reverse process) is outside of the workable area. Remedy: Connect the drive with a PC and start DriveTop. In the dialog box „Scaling/Mechanical system" select a scaling setting. Should another scaling installation other than one from DriveTop be used, then the following parameters must be checked.

                                               

Our products

A company specializes in the sales of module spare parts of global famous brands (DCS system) (robot system) (large servo control system). The company's products include distributed control system (DCS), programmable controller (PLC), MOTOROLA MVME industrial module, industrial control communication converter (Anybus), remote output/input module (RTU), industrial computer (IPC), industrial low screen screen (IPC) HMI SCSI (50, 68, 80Pin) AnyBus (Gateway) has become a global sales enterprise of industrial automation spare parts and components

Payment method and delivery

Shipment: EMS,DHL,UPS & FEDEX

Payment: T/T or Western Union

Obtain the latest price of ABB PFSK 102 YM322001-EG Pulse input module