Home > Product > Servo control system > HIMA F8560X processor module

  • HIMA F8560X processor module
  • HIMA F8560X processor module
  • HIMA F8560X processor module
HIMA F8560X processor module HIMA F8560X processor module HIMA F8560X processor module

HIMA F8560X processor module

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

HIMA F8560X processor module

The access level is automatically re - set after 5 hours or after power failure. Exception: If the automatic gas burner control system makes a restart during these 5 hours, for example due to an error, these 5 hours for the current ac - cess level are counted again from the beginning. Note: We recommend resetting the ac - cess level after having configured the automatic gas burner control system.Gas valves The valve connection may be configured, see section "Parameter description" - P38. Flame detector See Annex - Flame detector. For the connection of a second flame detector, see section "Parameter description" - P18. Air pressure switch See section "Parameter description" - P16 Gas pressure detector See section "Parameter description" - P18 Limit switch / POC Proof of Closure See section "Parameter description" - P18 Parameter mode (manual operation) A switch in the connection chamber is used for switching between parameter and automatic mode. The MPA registers a switching operation not before a restart.

Switch on "Auto" With this switch position, the MPA is working in normal operation. If a monitored parameter was changed and not released the MPA indicates an error with 0x60.

MPA 4112/MPA 4122

 After connecting the mains supply in Parametermode, a messages is prompted on the display requesting you to enter the code. Enter the password for service or OEM level. After having changed the level, the selected parameters are activated one after the other. See chapter MPA 4112/MPA 4122 Parameter display for parameters and sequence. The parameter values may be modified by pressing the keys + and -. The unlock key is used for saving the displayed value. Press the ← key to return to the previous position or parameter. As the display has two positions only, some values are represented in an optimised resolution. If the set value cannot be displayed in this resolution, the display shows "– –". The value may be changed in a resolution that can be displayed. If all parameters are set, there is an automatic start for checking the parameter values. The program stops in pause states; press a key to proceed (Hx is displayed). The set parameter values will be applied when reaching the H5 state. If you do not press any key for 30 minutes in parameter mode, the program tries a restart.

Obtain the latest price of HIMA F8560X processor module