If link integrity checking has been enabled by the host, you may later disable it with the LIT command. Check for proper link integrity control in the following manner. 1. Turn the generators AC power ON via the main AC breaker switch.
2. Turn the RF power on via the front panel.
3. Send a [^W] by pressing the W key while holding down the CTRL key. Within one second the RF power should go off because another [^W] was not sent.
4. Try to turn the RF power back on via the front panel. It should not go on.
5. Enter the command RFV=. The generator should return a Link Integrity fault.
Enter the command LIT.
Again enter the RFV= command. The generator should now show no faults, and you should be able to turn RF power on via the front panel.
With the RF power on send many [^W] in succession. Make sure you send at least one every second and ensure the RF power stays on while you are sending the [^W]. Once you stop sending the [^W], the RF should go off as it did before. Reset the generator with the LIT command again.
Troubleshooting
This chapter lists the common problems and solutions a user may encounter when using the GHW-25 / GHW-50 Genesis generator. If the problem doesn’t match any of those on the following pages, please contact the nearest ENI Service location for assistance.Contact an authorized ENI Service location for assistance. Interlock string open Check cabinet and RF interlocks; check that the interlock pins of analog interface are connected together. Refer to the Analog Interface, Table 3.3.1.
Company introduction
Temporal Ming sheng automation equipment co., LTD. Was established in April 02, 2021, registered jiujiang ruichang city in jiangxi province, east yi road no. 23 lake farmers 401 mall, the legal representative person Zhou Zuochen.
[Main Products]
Main products: PLC and DCS system spare parts modules of world famous brands
①Allen-Bradley 1756、1746、1747、1771、1785
②Schneider 140 Series PLC module
③General electric GE
IC693 IC697 IC698 Series PLC module
DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module
VMIVME Control module of series
④Bently:3500 series cards 3500/22M、3500/15、3500/92 And other products
⑤ICS TRIPLEX
⑥ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦EMERSON:Spare parts for OVATION system, WDPF system and MAX1000 system.
⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.
⑨Woodward:505 series governor 9907-164 And other products
⑩Bosch Rexroth:Indramat,I/O module,PLC CPU,Motors, drives and other products.
◆Motorola:MVME 162、MVME 167、MVME1772、MVME177and other products.