Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Using the standard baseplate, the FCP280 supports the following devices on the 268 Kbps fieldbus: • 100 Series FBMs • SPECTRUM™ Migration Integrators • SPEC 200™ Control Integrators • SPEC 200 MICRO™ Control Integrators • SPEC 200 CCM Control Integrators The Foxboro Gas Chromatograph is not supported.The FCP280 supports the 100 Series Fieldbus Module Upgrade subsystem, with the optional FBI200A modules. See 100 Series Fieldbus Module Upgrade Subsystem Overview (PSS 41H-2W100). FCP280 Baseplate The FCP280 is installed on a modular, DIN rail mounted baseplate in a dedicated slot that is keyed for the controller so that modules are not misplaced. The available FCP280 baseplates are shown in this figure.
These 2-position baseplates support a non-fault-tolerant single or fault-tolerant pair of FCP280s, as well as two copper (RH924UQ) or fiber (RH924WA) adapters, required for connection to the Control Network. The FCP280 baseplate provides support for four HDLC fieldbuses (PIO channels). On the standard baseplates, Fieldbus port 1 can be terminated, if needed, by the DIP switches provided on the baseplate. Fieldbus ports 2-4 are internally terminated in the FCP280 baseplates and no external hardware or switches are required for their termination. All four Fieldbus port pairs (A/B) on the dual cable baseplate are internally terminated by default without the use of DIP switches.
The FCP280 baseplates can be added in the field to existing or new configurations. The standard FCP280 baseplates have similar dimensions as the FCP270 2-position baseplates for ease of replacement, while the dual cable baseplates are larger and wider. When upgrading existing CP60 systems to use FCP280s, you can recover an additional two FBM positions after removing the old FCM10E/FCM10Efs. The following splitters and terminators can be used with FCP280 baseplate: • The Fieldbus Baseplate Terminator (P0916RB) is used to terminate either the CP end of the HDLC fieldbus or the last 200 Series baseplate in the daisy chain when Time Strobe or split A/B fieldbus cables are not required.For standard baseplates only, Fieldbus Baseplate Terminator/Splitter (RH924ZJ for Fieldbus port 1, or RH928CY for the Fieldbus port on a standard FCP280 baseplate) allows splitting of the A and B Module Fieldbus signals into different cables. This splitter can be used to interconnect optional redundant cables between FCP280 baseplates and 200 Series baseplates. It can also be used to terminate both the fieldbus and time strobe signals.