Home > Product > DCS control system > ABB SDCS-IOB-3 3BSE004086R1 Channel smart card

  • ABB SDCS-IOB-3 3BSE004086R1 Channel smart card
ABB SDCS-IOB-3 3BSE004086R1 Channel smart card

ABB SDCS-IOB-3 3BSE004086R1 Channel smart card

ABB SDCS-IOB-3 3BSE004086R1 Channel smart card

Once LOL is deasserted, the frequency-locked loop is turned off. The PLL/DLL pulls in the VCO frequency the rest of the way until the VCO frequency equals the data frequency. The frequency loop requires a single external capacitor between CF1 and CF2, Pin 14 and Pin 15. A 0.47 µF ± 20%, X7R ceramic chip capacitor with < 10 nA leakage current is recommended. Leakage current of the capacitor can be calculated by dividing the maximum voltage across the 0.47 µF capacitor, ~3 V, by the insulation resistance of the capacitor. The insulation resistance of the 0.47 µF capacitor should be greater than 300 MΩ.

Normal Mode

 In normal mode, the ADN2816 is a continuous rate CDR that locks onto any data rate from 10 Mb/s to 675 Mb/s without the use of a reference clock as an acquisition aid. In this mode, the lock detector monitors the frequency difference between the VCO and the input data frequency, and deasserts the loss-oflock signal, which appears on Pin 16 (LOL), when the VCO is within 250 ppm of the data frequency. This enables the D/PLL, which pulls the VCO frequency in the remaining amount and acquires phase lock. Once locked, if the input frequency error exceeds 1000 ppm (0.1%), the loss-of-lock signal is reasserted and control returns to the frequency loop, which begins a new frequency acquisition starting at the lowest point in the VCO operating range, 10 MHz. The LOL pin remains asserted until the VCO locks onto a valid input data stream to within 250 ppm frequency error. This hysteresis is shown in Figure 15.

INPUT BUFFER 

The input buffer has differential inputs (PIN/NIN), which are internally terminated with 50 Ω to an on-chip voltage reference (VREF = 2.5 V typically). The minimum differential input level required to achieve a BER of 10−10 is 200 mV p-p. LOCK DETECTOR OPERATION The lock detector on the ADN2816 has three modes of operation: normal mode, REFCLK mode, and static LOL mode.

                                           

Company introduction

Temporal Ming sheng automation equipment co., LTD. Was established in April 02, 2021, registered jiujiang ruichang city in jiangxi province, east yi road no. 23 lake farmers 401 mall, the legal representative person Zhou Zuochen.

[Main Products]

Main products: PLC and DCS system spare parts modules of world famous brands

①Allen-Bradley 17561746174717711785

②Schneider 140 Series PLC module

③General electric GE

IC693 IC697 IC698 Series PLC module

DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module

VMIVME Control module of series

④Bently3500 series cards 3500/22M3500/153500/92 And other products

⑤ICS TRIPLEX

⑥ABB Robots. FANUC RobotsYASKAWA RobotsKUKA RobotsMitsubishi RobotsOTC RobotsPanasonic RobotsMOTOMAN Robots

EMERSONSpare parts for OVATION system, WDPF system and MAX1000 system.

⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.

Woodward505 series governor 9907-164 And other products

⑩Bosch RexrothIndramatI/O module,PLC CPU,Motors, drives and other products. 

◆MotorolaMVME 162MVME 167MVME1772MVME177and other products.

Obtain the latest price of ABB SDCS-IOB-3 3BSE004086R1 Channel smart card