Home > Product > DCS control system > ABB 3BHB017688R001 Serial Link Controller

  • ABB 3BHB017688R001 Serial Link Controller
ABB 3BHB017688R001 Serial Link Controller

ABB 3BHB017688R001 Serial Link Controller

ABB 3BHB017688R001 Serial Link Controller

E-DONPISHA® function The E-DONPISHA function is used to read a field still picture in arbitrary timing without stopping any moving object. The delay time between the trigger input and exposure start is approximately 2 µs, and an instantaneous picture can be obtained without missing the shot timing. The still picture obtained using an external trigger signal is always used as the information that is read from the oddline gate of CCD. The field accumulation mode in which the sensitivity becomes double is selected because an electronic shutter is used. NON RESET mode A continuous composite sync signal is contained in the trigger standby video signal. The vertical synchronization of the video signal is not disturbed by the trigger input signal. However, the video sync signal by the trigger output is undefined. (odd/even) External synchronization can be used. A video output timing pulse is used as the second vertical sync signal after a trigger pulse is input. The operating mode is selected when solder jumper JR106 on the SG-218 board is set from open to short.

RESET mode

A continuous composite sync signal is contained in the trigger standby video signal. When a trigger pulse is input, the composite sync signal is reset and the vertical synchronization is disturbed. Therefore, only internal synchronization is used. The sync signal of a trigger output video signal is always used as the first field (odd) picture. RESET modes (1) and (2) are selected by the output timing of a video signal. RESET mode (1) The timing pulse of a video output signal is used as the first vertical sync signal immediately after a trigger pulse is input. Therefore, the operating mode in this case is fastest in the E-DONPISHA® function. This mode is set at the factory. RESET mode (2) The timing pulse of a video output signal is used as the third vertical sync signal after a trigger pulse is input. The operating mode is selected when switch S201-4 on the AT-86 board is set from OFF to ON.

Restart Reset of internal synchronization

The Restart Reset functions are used to generate a timing pulse using a trigger signal and obtain the frame or field picture of a still subject. A long-time exposure picture is also obtained by lengthening the interval of a trigger signal. For the conventional Restart Reset functions, continuous horizontal drive signals (HD) and 2 to 4 vertical drive signals (VD) must be input to the camera. For new Restart Reset functions, a sync signal can be generated inside the camera using an external trigger signal. These functions make the operation easy. The number of VD signals to be generated inside the camera is 1 to 4. This mode can be set in a camera menu. The first picture after a trigger pulse is input is saturated, so use the second picture. The picture after a trigger pulse is input is interlaced from the first field (odd) picture.

                                           

Company introduction

Temporal Ming sheng automation equipment co., LTD. Was established in April 02, 2021, registered jiujiang ruichang city in jiangxi province, east yi road no. 23 lake farmers 401 mall, the legal representative person Zhou Zuochen.

[Main Products]

Main products: PLC and DCS system spare parts modules of world famous brands

①Allen-Bradley 17561746174717711785

②Schneider 140 Series PLC module

③General electric GE

IC693 IC697 IC698 Series PLC module

DS200 DS3800 DS215 IS200 IS215 IS220 Series gas turbine module

VMIVME Control module of series

④Bently3500 series cards 3500/22M3500/153500/92 And other products

⑤ICS TRIPLEX

⑥ABB Robots. FANUC RobotsYASKAWA RobotsKUKA RobotsMitsubishi RobotsOTC RobotsPanasonic RobotsMOTOMAN Robots

EMERSONSpare parts for OVATION system, WDPF system and MAX1000 system.

⑧ Invensys Foxboro: I/A Series system, FBM (field input/output module) sequential control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing, data communication and processing, etc. Invensys Triconex: redundant fault-tolerant control system, Zui modern fault-tolerant controller based on triple module redundancy (TMR) structure.

Woodward505 series governor 9907-164 And other products

⑩Bosch RexrothIndramatI/O module,PLC CPU,Motors, drives and other products. 

◆MotorolaMVME 162MVME 167MVME1772MVME177and other products.

Obtain the latest price of ABB 3BHB017688R001 Serial Link Controller