Home > Product > DCS control system > ABB UNS0880a-PV2 3BHB005922R0002 Redundant channel module

  • ABB UNS0880a-PV2 3BHB005922R0002 Redundant channel module
ABB UNS0880a-PV2 3BHB005922R0002 Redundant channel module

ABB UNS0880a-PV2 3BHB005922R0002 Redundant channel module

ABB UNS0880a-PV2 3BHB005922R0002 Redundant channel module

Disconnect the AC power. Disconnect motor cable and cycle the J1 120/240 Vac 60/50 Hz power Off and On. If the PROCESSOR FAULT LED is OFF, check motor cable and motor for shorts across the windings or between the windings and the motor case. Drive faults while decelerating. Drive internal bus over voltage. Measure drive internal bus voltage at J6-1 and J6-2 (66 Vdc Out) with a storage oscilloscope during deceleration. If regeneration causes the bus voltage to exceed 84 V, verify the system load inertia to insure that the 66 Vdc out limit is never exceeded.

Measure the +5 V Logic Supply at J7-4 to J7-1 and J10-7 to J10-6 within +5V (±5%). Note: The total 5 Vdc current from pins J7-4, J11-8 and J10-7 must be less than 450 mA.

 Communications Interface Faul

t Procedure Follow this procedure if the terminal does not communicate with the indexer/drive: SYMPTOM CORRECTIVE ACTION 6445 will not respond to commands over serial link Verify that baud rate and COM port are set correctly in PacCom. Check that terminal transmit and receive lines from computer go to receive and transmit lines on the 6445. (See Section 2.5.4) Verify that serial cable is functioning properly. 1. Disconnect serial cable. 2. Short pins2&3 (See Section 2.5.4) 3. Type a character on keyboard. 4. Verify that character entered echoes back to screen.

Return procedure 

1. Call Pacific Scientific at (815) 226-3100 from 8:00 a.m. to 5:00 p.m. Eastern Standard Time to get a Returned Materials Authorization Number (RMA#). Note: Do not attempt to return the drive, motor or any other equipment without a valid RMA#. Returns received without a valid RMA# are not accepted and are returned to the sender. 2. Pack the drive in its original shipping carton. Pacific Scientific is not responsible or liable for damage resulting from improper packaging or shipment. 3. Ship the 6445 to: Pacific Scientific 110 Fordham Road Wilmington, MA 0188

                                          

Company product range

----------------------Ruichang Mingsheng Automation Equipment Co., Ltd----------------------

PLC module, programmable controller, CPU module, IO module, DO module, AI module, DI module

Network communication module,

Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output

Module, redundancy module, power module, relay output module, relay input module, processor module