Always remove power from TB1 before working on the machine or working anywhere where injury can occur due to machine motion.The temperature of the drive’s heat sink and housing as well as an external regen resistor can exceed 70°C. Therefore, there is a danger of severe burns if these regions are touched.
Avoiding Electrical Shock
Never power the servo drive with the cover removed or with anything attached to circuitry inside the cover. If the drive must be removed from the cabinet, wait at least five minutes after turning off power before removing any cables from the drive or removing the drive from the mounting panel. Never connect or disconnect any wiring to the drive while power is applied. Always power down and wait five minutes before connecting or disconnecting any wires to the terminals.
Preventing Damage to the Drive
Follow these guidelines to prevent damage to the servo drive during operation: • Never plug or unplug connectors with power applied. • Never connect or disconnect any wires to terminals with power applied • Never plug or unplug an option card with control power applied • If the drive indicates a fault condition, find the cause of the fault and fix it prior to resetting the fault or power-cycling the drive.
Brand display
ABB、GE/FUANC、FOXBORO、TRICONEX 、BENTLY、A-B、EMERSON 、MOTOROLA、XYVOM、HONEYWELL 、REXROTH、KUKA、NI、DEIF、Yokogawa、WOODWARD、Reliance Electric、SCHNEIDER 、MOOG、PROSOFT、KOLLMORGEN、ICS TRIPLEX、HIMA
This article from the temporal Ming sheng automation equipment co., LTD., reproduced please attach this link: http://www.stockdcs.com/