Home > Product > DCS control system > CI854 3BSE025349R1 Control module

  • CI854 3BSE025349R1 Control module
  • CI854 3BSE025349R1 Control module
  • CI854 3BSE025349R1 Control module
CI854 3BSE025349R1 Control module CI854 3BSE025349R1 Control module CI854 3BSE025349R1 Control module

CI854 3BSE025349R1 Control module

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

CI854 3BSE025349R1 Control module

The transducer is connected using a 4-pin mating connector Pg7-G5W1F, which must be ordered separately stating material no. R900023126. Up to a length of 50 m we recommend the use of a connection cable 4 x 0.25 mm² of type LiYCYCY. When double shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics. Oil-immersed pump: In conjunction with this pump type, the swivel angle transducer is installed oilimmersed. We recommend the use of cable type ÖLFLON® PTFE/FEP 4 x 0.25 mm² (by Lapp Kabel). When double shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics.

Swivel angle transducer DK100 can be connected using a 5-pin mating connector 130-9 IEC-22 to DIN 45 321, which can be ordered separately. Up to a length of 50 m we recommend the use of 4 x 0.25 mm² cables of type LiYCYCY as connection cable. When double shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics.

Establishing operational readiness

 To establish operational readiness of the control electronics: 1. Thoroughly inspect the cabling 2. Apply voltage to the control electronics VT-VPCD The control electronics runs a short internal function test. The display of the control electronics shows the manufacturer’s name in red scrolling text (during initial commissioning). See Chapter 5.2.3 “Display and operating elements and test sockets“ on page 23. The transducer is connected by means of soldered connections. Up to a length of 50 m we recommend the use of 3 x 0.5 mm² cables of type LiYCYCY as connection cable. When double-shielded cables are used, the outer shield can be terminated at the entrance in the control cabinet, the outer shield can be terminated at the control electronics. For the voltage interface, pressure transducers of type HM 20 -2X/...H-K35 are used. Pressure transducer cables must be shielded. Cable type for the voltage interface: LiCYC 4 x 0.25 mm2 up to a length of 50 m.

The proceeding for commissioning the control electronics VT-VPCD depends on various factors on site. For this reason, only basic steps for commissioning can be described in these instructions.

Obtain the latest price of CI854 3BSE025349R1 Control module